Programmable Attributes 
Supervisor Code
Remote Access
Duress Code
Bell Squawk upon Arming/Disarming
Zone Bypassing Enabled
One Time Use Code
Bell Squawk Attribute
This attribute is used to determine whether an access code should generate an arming/disarming Bell 
Squawk upon entry of the code for Away arming. The wireless keys with access codes associated with 
them may generate Arming/Disarming Bell squawks. If desired, this option may be used with codes that 
are manually entered. Please contact your installer to have this programmed.
NOTE: The Master Code cannot use the Bell Squawk attribute, but is required to enable it for 
other codes. 
NOTE: This feature cannot prevent the Arming/Disarming squawks from being generated if an 
access code assigned to a wireless key is manually entered at a keypad.
Setting an Access Code
1. Select “Set Access Code”. A keypad screen is shown with the existing code. If there is no exist-
ing code, “AAAA” (or AAAAAA for 6 digits) is shown.
2. Start to enter a new code. The code area will be cleared, and the new code will be shown. If the 
clear key is pressed, the new code will be cleared, but the old code is not deleted by this action. 
Once the last digit is entered the new code will have replaced the old code; no further action is 
required to save the code. If the screen “times out” (goes grey or black) or you exit the screen 
without completing the new code, the previous code will remain.
Proximity (Prox) Tag Enrollment and Use (WTK5504P keypad only)
More > User Options > Access Code Programming > Select User screen > 
User xx settings > Prox Tag Programming
Enrolling Proximity Tags
1. Press the Access Code Programming button, then “Set Access Code”. 
2. Enter your desired 4- or 6-digit user access code.
3. Press Prox Tag Programming. 
4. Place the prox tag near the tag reader 
 at the top of the keypad to assign it to the user code. The 
message “Tag Enrolled Successfully” will be displayed and the keypad will beep. If the proxim-
ity tag has been enrolled previously, an error tone will sound. The screen will read “Duplicate 
Tag/User Code”.
NOTE: Prox tags do not work on PowerSeries panels.   
Erasing Prox Tags
Delete tags from the system when they are lost or no longer needed. To delete a proximity tag, the user 
code it is associated with must be deleted.
1. Press More > User Options > Access Code Prog. [Master Code].
2. Use left and right arrow buttons to select the user number associated with the proximity tag to be 
deleted and press Select.
3. L CE  LgEPEIELt ECLGAULOBArTCbLedLaCE  TA:L
, E  x 
Replacing Existing Prox Tags
To keep the same user code and number, but enrol a new tag due to loss of the old one 
1. Press More > User Options > Access Code Prog. [Master Code].
2. Use left and right arrow buttons to select the user number associated with the proximity tag and 
press Select.
3. Choose “Replace Prox Tag” from the menu options. 
4. Place the prox tag near the tag reader 
 at the top of the keypad. The message “Tag Enrolled 
Successfully” will be displayed and the keypad will beep.
User Options
Erasing an Access Code
To erase a code, select the code and choose Delete User. The system will delete the code immediately 
and the user will be returned to select another code.