Digital Security Controls Ltd. 163G4005 User Manual

Page of 49
4005 Series
23
SMS 
Send an SMS consisting of the User code between the * characters, the Control string (Control String can not have initial blank
spaces) and the characters “=ON*”, “=ON*TonU*” or “=OFF*”, as follows:
#User Code*String=ON* 
#User Code*String=ON*TonU*
#User Code*String=OFF*
The “=ON*tonU*” option is parameter allows to set the ON Time from 1 to 86400 seconds, with 1 second steps. The ON Time can
be set by means of the Communicator's Console software. “Ton” is the required value and “U” is the unit in hours (H), minutes (M)
and seconds (S), as shown in the following example:
Remove the “TonU” parameter, leaving the “**” characters, to activate the output by SMS as programmed. (Example:
#9876*heating system=ON**).
In case of wrong programming for the Activation of the monostable Output, it will be activated with the time value set in the
software DLS 5. 
Caller Identification
Through Caller identification (Caller ID): in this case the output is activated at “cost-free” as the Communicator, after identifying the
caller, rejects the call and activates the output.
Monostable OC outputs deactivate (switch OFF) automatically when the programmed ON Time expires.
Only the T3 output can be activated through Caller Identification.
The ON time may be set to a period of time between 1 and 86400 seconds, in steps of 1 second.
The default User code is ‘000000’; if you wish to change it, please refer to the section “Remote programming by SMS message-
>Changing the User code”.
SMS example
Meanings
#9876*HEATING SYSTEM=ON*
Bistable activation.
#9876*HEATING SYSTEM=ON**
Active as programmed.
#9876*HEATING SYSTEM=ON*3600S*
Active for 3600 seconds.
#9876*HEATING SYSTEM=ON*50M*
Active for 50 minutes.
#9876*HEATING SYSTEM=ON*3600*
Active as programming, invalid Monostable timing, will be ignored.
#9876*HEATING SYSTEM=ON*000S*
Active as programming, invalid Monostable timing, will be ignored
#9876*HEATING SYSTEM=OFF*
Deactivate.