Digital Security Controls Ltd. 163G4005 User Manual

Page of 49
44
Universal Cellular Communicator
See the tables below.
An event for sending contact ID of “alarm intrusion / Tamper”, must be configured in case of activation of Input 1, event and
an event for sending contact ID of “fault”, in case of activation of Input 2 event.
Communicator
Control Panel
LI

LE
T1: Output “PSTN Fault”
T2: Output “No cellular network”
De
fau
lt
T3: “Panel interconnection Present”
Output “LE presence detection”
T4: Output “Tamper”
Input “Tamper” Communicator
T5: Output “GSM Fault”
Input “GSM Fault”
T6: Output “Jamming Detect”
Input “Jamming Detect”
Table 9: Wiring diagram A: with simulated PSTN.
Communicator
Control Panel
Default
T1: Input “alarm / tamper”
Output “Alarm /Tamper”
T2: Input “Fault”
Output “Fault”
T3: “Panel interconnection Present”
Input “Panel interconnection Present”
T4: Output “Tamper”+ “Jamming Detect”
Input “Tamper” Communicator
T5: Output “GSM Fault”
Input “GSM Fault”
T6: Output “IP receiver fail”
Input “Ack Fault”
Earth Terminal
Earth Terminal
Table 10: Wiring diagram B: without simulated PSTN.