Digital Security Controls Ltd. 163G4005 User Manual

Page of 49
4005 Series
43
APPENDIX
EN 50136-2: 2013 compliance
The Communicator, to comply to EN 50136-2: 2013, must be configured and connected to a Control Panel, only in one of two fol-
lowing ways, A or B:
A) use PSTN (the control panel will made the control, of the response of the receiver, directly on the PSTN).
PSTN: terminals LI of the communicator connected to terminals of the Control Panel for the external telephone line.
Terminal T4, configured as output “Tamper”, connected to the input of the Control Panel (only for the Communicator with
plastic box).
Terminal T5, configured as an output “GSM Fault”, connected to input of the Control Panel.
Terminal T3 of the Communicator configured as input “Panel interconnection Present”.connected to signal from the Control
Panel, indicating Panel Present and / or telephone line detected 
Terminal T6, configured as Output “jamming detected” connected to input “Jamming” of control panel.
You must setup at least one IP receiver.
B) not use of the PSTN
Terminal T4, configured as an output “Tamper” + “Jamming Detected”, connected to the input of the Control Panel (only for
Communicator with plastic box).
Terminal T5, configured as an output for “GSM Fault”, connected to the input of the Control Panel.
Terminal T1 configured as an input Alarm/Tamper, connected to output of signalling “alarm intrusion / tamper” of Control
Panel.
The “event input 1" to send the code “Intrusion alarm”.
Terminal T2 configured as an input, connected to output of signalling “Fault” of Control Panel.
The “event input 2" to send the code “Fault”.
Terminal T6 configured as an Output “IP receiver Fail”, connected to an Input of Control Panel. 
Terminal T3 of the communicator configured as Input “Panel interconnection Present” connected to a terminal of the Control
Panel of signalling “Control Panel present”.
The earth terminal of the communicator, will be connected to an Input of control panel, to detect the presence of interconnec-
tion between the central and communicator. 
In the Communicator page: “Central Stations calls”, for the two events “input 1 Event” and “input 2 Event” it must enter a
“Customer code” and select “Channel Type” value “CID/SIA over Data Network”. 
You must setup at least one IP receiver.