Digital Security Controls Ltd. 17PG9945E User Manual

Page of 4
PG9945E_PG4945E
PowerG 2-way Wireless Magnetic Contact Device 
with Hard-wired Input Installation Instructions
Operation
The PGx945E Series is a supervised, 2-way wireless PowerG
magnetic contact device. The device includes a built-in reed switch
and a separate N.O., N.C. or E.O.L programmable auxiliary hard-
wired input for use with other hardwired sensors.
The reed switch and the auxiliary input behave as separate
transmitters, although they trigger the same RF transmitter.
Removing the cover activates the tamper switch. If configured,
LED lights only when reporting alarm or tamper events. Built-in
link quality indicators reduce installation time by eliminating the
need for the installer to physically approach the control panel. The
PGx945E series includes enhancements to the PowerG transceiver
to ensure a longer wireless range than the PGx945.
Low-Battery Detection
The PGx945E includes low-battery condition detection. When this
condition is detected a trouble message is transmitted to the
compatible receiver/control panel. This will provide visual
identification of the unit that requires a battery change.
Device Setup
WARNING! To comply with FCC RF exposure compliance
requirements, the magnet contact device should be located at a
distance of at least 20 cm from all persons during normal operation.
The antennas used for this product must not be co-located or
operated in  conjunction with any other antenna or transmitter.
Note:  This equipment shall be installed and used within an
environment that provides the pollution degree max 2 and non-
hazardous locations, indoor only. It is designed to be installed by
service persons only [service person is defined as a person having
the appropriate technical training and experience necessary to be
aware of hazards to which that person may be exposed in
performing a task and of measures to minimize the risks to that
person or other persons].
CAUTION!
This product uses Lithium Batteries. Improper handling of lithium
batteries may result in HEAT GENERATION, EXPLOSION or
FIRE, which may lead to personal injuries. 
WARNING! 
Danger of explosion if batteries are installed incorrectly. replace
only with the same or equivalent type recommended by the
manufacturer. Dispose of used batteries according to the
manufacturer's instructions.
Keep away from small children: if swallowed promptly see a
doctor. 
Do not try to recharge these batteries.
Note: Battery replacement should be done by installer.
Note:  To ensure the continued operation of all wireless devices
after performing a system default, a global upload of all wireless
programming via DLS is recommended before defaulting the
system. After completing the system default, download the
wireless programming. 
Legend
A. Flexible Retainer
B. Break-away base segment (for back tamper)
C. PCB edge supports
D. Mounting holes
E.
Wiring inlet
F.
LED
G.
Terminal block for sensor
H. Enroll button
I.
Tamper switch
J.
Reed switch on underside of PC Board (in unit)
K. Symbol on side of the case indicates location of reed switch
L.
Magnet
M. 1/4" space maximum (6mm)
N. 47kΩ resistor
O. N.C. switch
P.
N.O. switch
Install the battery
1.
Insert a flat-edged screwdriver into 
the slot and push upward to remove 
cover.
2.
Remove the screw and separate the 
cover from the base.
3.
Observe polarity and install battery.
4.
Connect the sensor wire to the ter-
minal block.
Note: 
When manually programming
wireless devices, if a device has been
powered up for more than 48 hours it cannot
be enrolled into the system until the device
has been tampered and restored. When
programming the panel using the Quick
Enroll procedure follow the steps detailed in
Enroll the Device into the System.
Note:  After restoring a low battery trouble
the system may take up to 5 minutes to clear
the trouble.
Enroll the Device into the System
Refer to the PowerSeries Neo Host Installation Manual or iotega
Reference Manual for the enrollment procedure.
Placement Testing
Before permanently mounting any wireless device, temporarily
mount the device and perform a Placement test.
1.
Tamper the device by removing the cover.
2.
Replace the cover to restore the tamper.  The device now 
enters Placement test mode for 15 minutes. 
3.
Trip the device by opening the door or window and verify the 
red LED blinks, indicating detection.
4.
After 2 seconds the LED blinks 3 times.The following table 
indicates received signal strength.
IMPORTANT!  Only GOOD or STRONG signal strengths are
acceptable. If you receive a POOR signal from the device, re-locate
it and re-test until a GOOD or STRONG signal is received. 
Note: After installation verify the product functionality in
conjunction with the compatible receivers HSM2HOST9/
HSMHOST4,HS2LCDRF(P)9/HS2LCDRD(P)4, HS2ICNRF(P)9/
HS2ICNRF(P)4, PG9920/PG4920, WS900-19, and WS900-29.
Note: For detailed Placement instructions refer to the control panel
Reference Guide
Gap Separation
Mounting the Device
It is highly recommended to attach the transmitter to the top of the
door/window on the fixed frame and the magnet to the door or
window. Ensure that the magnet is located not more than 6 mm
(0.25 in.) from the transmitter’s marked side. 
Note: Once the cover is removed, a tamper message is transmitted
to the receiver. Subsequent removal of the battery prevents
transmission of tamper restore, leaving the receiver in permanent
alert. To avoid, press the tamper switch while removing the battery.
Attention!
The unit has an optional back tamper switch under the PCB. As
long as the PCB is seated firmly within the base, the switch lever
will be pressed against a special break-away base segment that is
loosely connected to the base. Be sure to fasten the break-away
segment to the wall. If the detector unit is forcibly removed from
the wall, this segment will break away from the base, causing the
tamper switch to open.
Mounting with screws
1.
With the cover removed, flex retainer and remove PCB. 
2.
Mark & drill 2 holes in mounting surface.
3.
Fasten base with 2 countersunk screws.
4.
Mount the magnet base with 2 supplied screws.
5.
Attach the magnet to the magnet base.
Mounting with adhesive tape
1.
Peel away the release liners from the two strips of double-
sided adhesive tape and attach to the device and magnet.
2.
Align the device with the magnet according to the location 
marks and fasten the device and magnet to the mounting sur-
face.
Auxiliary Input wiring
1.
Connect the auxiliary sensor contacts across the auxiliary 
input terminals.
2.
If the auxiliary input is defined as a Normally Closed (N.C.) 
type, series connected N.C. sensor contacts must be used 
exclusively. An E.O.L. resistor will not be required. 
3.
If the auxiliary input of the is defined as a Normally Open 
(N.O.) type, parallel connected N.O. sensor contacts must be 
used exclusively. An E.O.L. resistor will not be required.
4.
For E.O.L. supervision: Normally Closed (N.C.) sensor con-
tacts can be used. A 47kΩ E.O.L. resistor must be wired at the 
far end of the zone loop.
The drawing below illustrates a N.O. and N.C. alarm circuit with
E.O.L. resistor.
Note: An alarm message is transmitted once the loop is opened or
short circuited.
Configuration
The following programmable options are available.
Selections
Specifications
Frequency Band (MHz): PG4945E: 433MHz; PG9945E: 912-
919MHz band.
Communication Protocol: PowerG
Alarm Input: One internal
Supervision: Signaling at 4-min. intervals
Tamper Alert: Reported when a tamper event occurs
Battery type: 3 V Lithium CR-123A type battery GP
Battery Life Expectancy: 8 years (for typical use)
Battery Supervision: Automatic transmission of battery condition
data as part of periodic status report and immediately upon low
battery condition detection
Temperature range: -10ºC to +55ºC
Relative Humidity: up to max. 93%RH, non-condensing
Dimensions (LxWxD): 81 x 34 x 25 mm (3-3/16 x 1-1/4 x 1 in.)
Weight (including battery): 53g (1.9 oz)
Auxiliary Input Cable Length: 10m max, AWG22
Auxiliary Input EOL Resistor: 47KΩ
Installed by qualified installers and for use in indoor non-
hazardous locations only.
Low Battery trouble level: 2.2V
Compatible Receivers
This device can be used with DSC panels and receivers that use 
PowerG technology.
FCC COMPLIANCE STATEMENT
WARNING! Changes or modifications to this unit not expressly approved by the party responsible for compliance could void
the user’s authority to operate the equipment.
This device has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC
Rules. These limits are designed to provide reasonable protection against harmful interference in residential installations.
This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio and television reception.
However, there is no guarantee that interference will not occur in a particular installation. If this device does cause such
interference, which can be verified by turning the device off and on, the user is encouraged to eliminate the interference by
one or more of the following measures:
– Re-orient or re-locate the receiving antenna.
– Increase the distance between the device and the receiver.
– Connect the device to an outlet on a circuit different from the one that supplies power to the receiver.
– Consult the dealer or an experienced radio/TV technician.
This equipment complies with FCC RF radiation exposure limits set forth for an uncontrolled environment.
This device complies with FCC Rules Part 15 standards. Operation is subject to the following two conditions: (1) This device
may not cause harmful interference, and (2) this device must accept any interference that may be received or that may cause
undesired operation.
WARNING! To comply with FCC and IC RF exposure compliance requirements, the device should be located at a distance of
at least 20 cm from all persons during normal operation. The antennas used for this product must not be co-located or
operated in conjunction with any other antenna or transmitter.
FCC ID: F5317PG9945E
PG9945E_PG4945E
Dispositivo de contacto magnético inalámbrico 
bidireccional PowerG con instrucciones de 
instalación de entrada cableada
Operación
El detector de la serie PGx945E es un dispositivo de contacto
magnético inalámbrico, bidireccional y supervisado de PowerG. El
dispositivo incluye un interruptor de láminas integrado y una
entrada cableada auxiliar programable separada N.A., N.C. o
E.O.L para uso con otros sensores cableados.
El interruptor de láminas y la entrada auxiliar se comportan como
transmisores separados, aunque activen el mismo transmisor de RF.
El retiro de la cubierta activa el interruptor contra manipulación. Si
está configurado, el LED se enciende solamente al indicar eventos
de alarma o manipulación. Los indicadores de calidad de enlace
incorporados reducen el tiempo de instalación al eliminar la
necesidad del instalador de acercarse físicamente al panel de
control. El PGx945E incluye mejoras en el transceptor PowerG
para asegurar un mejor rango inalámbrico que el PGx945.
Detección de batería baja
El PGx945E incluye la detección de la condición de batería baja.
Cuando se detecta esta condición, se transmite un mensaje de
avería al receptor compatible/panel de control. Esto proporcionará
identificación visual de la unidad que requiera un cambio de
batería.
Configuración del dispositivo
¡ADVERTENCIA! Para cumplir con los requisitos de seguridad
de exposición a la radiofrecuencia de la FCC, el dispositivo de
contacto del imán debe colocarse a una distancia mínima de 20 cm
de todas las personas durante la operación normal. Las antenas
usadas para este producto no deben ser colocadas u operadas
conjuntamente con ninguna otra antena o transmisor.
Nota: Este equipo deberá ser instalado y usado dentro de un
ambiente que proporcione ubicaciones no peligrosas de grado máx.
de contaminación 2 y exclusivo para interiores. Está diseñado para
ser instalado exclusivamente por personal de servicio [personal de
servicio se define como la persona que tenga la capacitación
técnica y experiencia necesarias para estar consciente de los
peligros a los que esa persona pudiera estar expuesta al ejecutar
una tarea y de las medidas para minimizar los riegos para esa
persona u otras personas].
¡PRECAUCIÓN!
Este producto utiliza baterías de litio. La manipulación incorrecta
de las baterías de litio puede producir GENERACIÓN DE
CALOR, EXPLOSIÓN o INCENDIO, lo que podría causar daños
personales. 
¡ADVERTENCIA! 
Peligro de explosión si las baterías están instaladas
incorrectamente. Reemplace las baterías solamente por el mismo
tipo o equivalente recomendado por el fabricante. Deseche las
baterías usadas según las instrucciones del fabricante.
Manténgalas alejadas de niños pequeños: si son ingeridas, consulte
inmediatamente a un doctor. 
No intente recargar estas baterías.
Nota: El reemplazo de la batería debe ser realizado por el
instalador.
Nota: Para asegurar la operación continuada de todos los dispositi-
vos inalámbricos después de realizar un puesta del sistema a sus
valores predeterminados, se recomienda realizar una carga global
de toda la programación inalámbrica vía DLS antes de poner el
sistema en sus valores predeterminados. Después de terminar la
puesta del sistema a sus valores predeterminados, descargue la pro-
gramación inalámbrica.
Leyenda
A. Retén flexible
B. Segmento base de ruptura (para manipulación trasera)
C. Soportes de borde de PCB
D. Agujeros de montaje
E.
Entrada de cableado
F.
LED
G.
Bloque de terminales para el sensor
H. Botón de asociar
I.
Interruptor contra manipulación
J.
Interruptor de láminas en la parte inferior de tarjeta de PC (en 
la unidad)
K. El símbolo en el lado de la caja indica la ubicación del 
interruptor de láminas
L.
Imán
M. ¼ pulg. de espacio como máximo (6 mm)
N. Resistencia de 47 kΩ
O. Interruptor N.C.
P.
Interruptor N.A.
Instale la batería
1.
Inserte un destornillador plano 
en la ranura y empuje hacia 
arriba para retirar la cubierta.
2.
Retire el tornillo y separe la 
cubierta de la base.
3.
Observe la polaridad e instale la 
batería.
4.
Conecte el conductor del sensor 
al bloque de terminales.
Nota: Al programar manualmente los
dispositivos inalámbricos, si un
dispositivo ha estado alimentado por
más de 48 horas, no podrá asociarse
en el sistema hasta que haya sido
manipulado y restaurado.
Nota:  Después de restaurar un
problema de batería baja, el sistema
puede tardar hasta 5 minutos para
eliminar el problema.
Asocie el dispositivo al 
sistema
Consulte el manual de instalación de
PowerSeries Neo Host o el manual de referencia iotega para
obtener más información sobre la asociación del dispositivo.
Prueba de colocación
Antes de montar permanentemente cualquier dispositivo
inalámbrico, monte el dispositivo temporalmente y realice una
prueba de colocación.
1.
Manipule el dispositivo mediante el retiro de la cubierta.
2.
Reponga la cubierta para restablecer la protección contra 
manipulación. El dispositivo ahora entra en el modo de prueba 
de colocación durante 15 minutos. 
3.
Dispare el dispositivo abriendo la puerta o la ventana y 
verifique que el LED rojo parpadea, indicando detección.
4.
Después de 2 segundos el LED parpadea 3 veces. La tabla 
siguiente indica la potencia de la señal recibida.
¡IMPORTANTE!  Solamente las potencias de señal BUENA o
FUERTE son aceptables. Si usted recibe una señal BAJA del
dispositivo, reubíquelo y vuelva a probarlo hasta que reciba una
señal BUENA o FUERTE. 
Nota: Después de la instalación, verifique la funcionalidad del
producto junto con los receptores compatibles HSM2HOST9/
HSMHOST4,HS2LCDRF(P)9/HS2LCDRD(P)4, HS2ICNRF(P)9/
HS2ICNRF(P)4, PG9920/PG4920, WS900-19 y WS900-29.
.Nota: Puede encontrar instrucciones detalladas sobre la
colocación en la Guía de referencia del panel de control
Separación de la luz
Montaje del dispositivo
Es altamente recomendado fijar el transmisor a la parte superior de
la puerta/ventana en el marco fijo y el imán a la puerta o ventana.
Asegúrese de que el imán esté ubicado a no más de 6 mm (0,25
pulg.) del lado marcado del transmisor. 
Nota: Cuando se ha retirado la cubierta, se transmite un mensaje de
manipulación al receptor. El retiro subsecuente de la batería impide
la transmisión de la restauración de manipulación, dejando el
B
A
C
D
E
F
LED response
Signal Strength 
Green LED blinks
STRONG 
Orange LED blinks
GOOD 
Red LED blinks
POOR 
No blinks
No communication
Metallic (Ferrous) 
Materials
Nonmetallic/Metallic 
(nonferrous) Materials
Direction of 
Movement of 
the Magnet
Approach/
Make
Remove/
Break
Approach/
Make
Remove/
Break
Axis X
8 mm (.31”) 11 mm 
(.43”)
19 mm 
(.75”)
23 mm 
(.91”)
Axis Y
8 mm (.31”) 9 mm 
(.35”)
14 mm 
(.55”)
15mm (.59”)
Axis Z
7 mm (.28”) 13 mm 
(.51”)
24 mm 
(.94”)
30 mm 
(1.18”)
Recommended maximum gap separation for installation (on speci-
fied materials and axes of use) is 6mm (0.24”). 
+
-
H
I
G
}
J
L
K
M
Z
X
Y
Alarm LED - 
Default [Y]
Enables the devices LED to activate
when an alarm event occurs.
Reed Switch - 
Default [Y]
Enables\disables the reed switch.
External Input - 
Default [N]
Enables\disables the external input.
Supervision - 
Default [Y]
Enables supervision of the device.
[002]
Zone EOL - Default [01]
Configures auxiliary input as on of the following options:
[00] Disabled
[01] Single EOL
[02] Normally 
Open
[03] Normally Closed
N
O
P
B
A
C
D
E
Respuesta del LED
Intensidad de señal 
El LED verde parpadea
FUERTE 
El LED naranja parpadea
BUENA 
El LED rojo parpadea
BAJA 
No parpadea
Ninguna comunicación
Materiales metálicos 
(ferrosos)
Materiales no-metálicos/
metálicos (no ferrosos)
Dirección del 
movimiento 
del imán
Acerca/
Contacto
Retira/
Ruptura
Acerca/
Contacto
Retira/Rup-
tura
Eje X
8 mm 
(0,31 pulg.)
11 mm 
(0,43 
pulg.)
19 mm 
(0,75 pulg.)
23 mm 
(0,91 pulg.)
Eje Y
8 mm 
(0,31 pulg.)
9 mm 
(0,35 
pulg.)
14 mm 
(0,55 pulg.)
15 mm 
(0,59 pulg.)
Eje Z
7 mm 
(0,28 pulg.)
13 mm 
(0,51 
pulg.)
24 mm (,94 
pulg.)
30 mm 
(1,18 pulg.)
La separación de luz máxima recomendada para instalación 
(en materiales y ejes de uso especificados) es 6 mm (0,24 pulg.). 
F
+
-
H
I
G
}
J
L
K
M
Z
X
Y
DRAFT