XT30/XT50 Installation Guide
16
ComPlIanCe
NRTL Listed Specifications
19.1   Introduction
The programming and installation specifications contained in this section must be completed when installing
the XT30/XT50 in accordance with any of the ANSI/UL burglary standards. Additional specifications may be
required by a particular standard.
19.2  Bypass Reports
The bypass reports must be programmed as YES for all NRTL (National Recognized Testing Laboratory) Listed
burglary applications. 
19.3  Current Draw
The total current draw from a combination of auxiliary, smoke, and bell output terminals must not exceed
1.6 Amps. 
Household Burglar-Alarm System Units ANSI/UL 1023
20.1   Bell Cutoff
The bell cutoff time cannot be less than four minutes.  
20.2  Entry Delay
The maximum entry delay used must not be more than 45 seconds.
20.3  Exit Delay
The maximum exit delay used must not be more than 60 seconds. 
20.4  Wireless External Contact
When used, the External Contact of 1101 or 1102 must be programmed Normally Closed.
20.5  Wireless Supervision Time
The Zone Information Supervision Time cannot be set to 0 (zero).
20.6  Wireless Audible Annunciation
The Wireless Audible option must be selected as DAY for residential applications.
20.7  Panel location
Mount panel inside protected area or have tamper switch installed on enclosure. Zone 1 may be programmed
for Alarm on Tamper.
Digital Burglar Alarm Communicator System Units ANSI/UL 1635
21.1  Entry Delay
The maximum entry delay used must not be more than 60 seconds.  
21.2  Exit Delay
The maximum exit delay used must not be more than 60 seconds.  
21.3  Test Frequency
The Test Frequency option must be programmed to send a report once every 24 hours.
21.4  Automatic Bell Test
This option must be programmed as YES.
21.5  Central Station
Digital Dialer Central Station (DACT) service for commercial application can be provided under UL 1635 by
adding a listed local audible signal appliance and placing the XT30 or XT50 panel into the Model 350A Attack
Resistant Enclosure.