OUTPUT SETUP
output number extends battery life, but response time may be up to 15 seconds. 
A fast response output number responds within 1 second, but reduces battery life. 
Refer to the specific wireless output installation guide to determine battery life.
31.3 
Output Name
This section allows you to define a 16 character alphanumeric name for any 
wireless output.
An output that is not part of the system must be marked * UNUSED *. To mark an 
output unused, press any select key to display the default name, then press the 
COMMAND key. The pro grammer auto matically pro grams the name  
as * UNUSED *.
31.4 
Serial Number
Enter the eight-digit serial number found on the wireless device.
This message displays when the serial number is already programmed for another 
output or zone. The programmed output or zone number displays.
31.5 
Supervision Time
Press any top row key to select the supervision time required for the wireless 
output. Press COMMAND to accept the default time. Default is 240 minutes.
Select the required number of minutes. The transmitter must check in at least 
once during this time or a missing condition is indicated for that zone. 1100 Series 
transmitters automatically check in based on the supervision time selected for 
the wireless zone, no additional programming is needed. Zero (0) indicates an 
unsupervised transmitter.
The 3 minute supervision time is only available if using an 1135 or 1135DB  
Wireless Siren.
Note: When the panel is reset, a receiver is installed or powered down and 
powered up, or programming is complete, the supervision timer restarts for all 
wireless outputs.
31.6 
Trip with Panel Bell Option
This option displays when the wireless device is an 1135 or 1135DB wireless siren. 
Select YES to have the 1135/1135DB wireless siren follow the panel bell output. 
Default is YES.
Area Information
32.1 
Area Information
This section allows you to assign functions to individual areas for XTLplus panels. 
All non-24-hour zones must be assigned to an active area. See the section on  
Zone Information.
Activate an area by assigning it a name. A name is given to each active area to 
assist the user during arming and disarming.
32.2 
Area Number
Enter the number of the area to program. In an area system, select from  
areas 1 to 6. 
In an All/Perimeter system, select INTerior or PERIMeter. 
In a Home/Away system, select INTerior, BDRM, or PERIMeter.
32.3 
Area Name
In an area system, enter up to 16 characters for the area name. Only those areas 
given names can have zones assigned to them. All others are marked *UNUSED*.
To add an area name to the system, press any select key and then enter up to 16 
characters for the new name. Refer to the Entering Alpha Characters section. Press 
COMMAND to continue.
To mark an active area as unused, delete the old name by pressing any select key 
then press the COMMAND key. The panel automatically sets the name as *UNUSED*. 
If you have already Initialized the panel, all areas will be marked as *UNUSED*. See 
section 2.3.
32.4 
Automatic Arming
Select YES to allow this area to arm automatically according to the opening and 
closing schedule.
If Closing Check is selected as YES, the automatic arming does not take place  
* UNUSED *
SERIAL#: -
ALREADY USED:  ZXX
SUPRVSN TIME:  240
0       3      60    240
 
TRIP WITH PANEL
BELL
 NO YES
AREA INFORMATION
INT     
  PERIM 
AREA NO: -
INT     BDRM    PERIM
* UNUSED *
AUTO ARM  NO YES
AREA INFORMATION