XTLplus Installation and Programming Guide
28
OUTPUT OPTIONS
For example, If the Armed Output is F05, F06 activates when Sleep is armed.
When the system is armed 
HOME, the programmed Favorite plus 2 is activated.
For example, If the Armed Output is F05, F07 activates when Home is armed.
For an All/Perimeter system:
When the system is armed 
ALL, the programmed Favorite activates.
When the system is armed 
PERIMETER, the programmed Favorite plus 1  
is activated.
For example, If the Armed Output is F05, F06 activates when Perimeter is armed.
For an Area system:
When any area of the system is armed, the programmed Favorite activates.
30.10 
Disarmed Output
This output/Favorite turns on when all areas of the panel are disarmed. The output 
turns off when an area is armed.
30.11 
Burglary Output
This output/Favorite turns on any time a burglary zone goes into alarm. The output 
turns off when the area in which the alarm occurred disarms and no other burglary 
zones are in alarm. Enter 0 (zero) to disable this output.
30.12 
Arm-Alarm Output
Enter the output/Favorite to turn on steady when any area of the system is 
armed. If an alarm occurs causing the keypads to turn Red, this output pulses and 
continues to pulse for approximately three (3) minutes after the panel is disarmed. 
Enter 0 (zero) to disable.
Wireless Outputs
The Arm-Alarm Output is compatible with the Model 1117 Wireless LED 
Annunciator and the Model 1116 Wireless Relay Output connected to a Model 572 
Indicator LED.
When the Model 1117 is battery operated, the LED is off when the system is 
armed to conserve battery life. If an alarm occurs, the output flashes quickly.
When using the Model 1116 connected to a Model 572, the LED is on when the 
system is armed. If an alarm occurs, the output pulses.
To operate the Arm-Alarm output within one second, program a fast response 
number from 61 to 64. Fast response operation reduces overall wireless output 
battery life.
To operate the Arm-Alarm output within 15 seconds, program a slow response 
number from 51 to 54. Slow response operation increases overall wireless output 
battery life.
30.13 
Heat Saver Temperature
Enter the desired temperature setting for all Z-Wave thermostats when the system 
is armed ALL or AWAY. When the system is disarmed the thermostats return to their 
previous settings. The range is 55-95 degrees. Enter 0 (zero) to disable.
30.14 
Cool Saver Temperature
Enter the desired temperature setting for all Z-Wave thermostats when the system 
is armed ALL or AWAY. When the system is disarmed the thermostats return to their 
previous settings. The range is 55-95 degrees. Enter 0 (zero) to disable.
Output Setup
31.1 
Output Setup
This section allows you to program and name wireless outputs into the panel.
31.2 
Output Number
Enter an output number. Select from the following output numbers:
• 51 to 54 — Slow response time* wireless outputs (activate within 15 seconds)
• 61 to 64 — Fast response time* wireless outputs (activate within 1 second)
Note: Addresses 51 to 54 and 61 to 64 are available for wireless outputs or wireless 
key fob zones and can only be assigned to one device.
* The response time of a wireless output is the time it takes for a wireless output 
to activate once the panel event occurs. You determine whether a wireless output 
is a slow or fast response based on the output number assigned. A slow response 
DISARMED OUT:
0
BURGLARY OUT:
0
ARM-ALARM OUT:
0
HEAT SAVER
TEMPERATURE:
0
COOL SAVER
TEMPERATURE:
0
OUTPUT SETUP
OUTPUT SETUP
OUTPUT NO: -