AREA INFORMATION
until the expiration of a 10-minute Closing Check delay. If the area has been 
disarmed outside a schedule, the Closing Check delay occurs one hour after the 
area is disarmed.
At arming, faulted zones are handled according to the option selected in Bad 
Zones. If a Closing report is sent, the user number is indicated as SCH on the SCS-
1R Receiver. Select NO to disable automatic arming for this area. Default is NO.
32.4.1 
Bad Zones
At the time of automatic arming, some zones in the area may not be in a normal 
condition. This option allows you to program the panel’s response to these bad 
zones. This option is not displayed if AUTO ARM is NO. 
BYP - All bad zones are bypassed. A report of the bypass is sent to the receiver 
if Bypass Reports has been selected as YES. See the Bypass Reports section. The 
report indicates SCH as the user number.
FORC - All bad zones are force armed. Zones force armed in a bad condition are 
capable of restoring into the system and reporting alarms if tripped. A report of 
the force arm is sent if Bypass Reports is YES. See the Bypass Reports section. The 
report indicates the user number as SCH.
REF - The automatic arming is refused and no arming takes place. A No Closing 
report is sent to the receiver regardless of the Closing Check selection.
Note: For listed installations, set Bad Zones to REF.
32.5 
Automatic Disarming
NO disables automatic disarming by schedule for this area. Select YES to allow this 
area to automatically disarm according to a schedule. If an Opening report is sent 
to the receiver, the user number is indicated as SCH.
Zone Information
33.1 
Zone Information
This allows you to define the operation of each protection zone used in the system.
33.2 
Zone Number
Zone numbers on the XTLplus panel default to the following settings. The settings 
can be changed as described in the following sections. Zones 51-54 can be wireless 
zones, key fobs or slow outputs. Zones 61-64 can be wireless zones, key fobs, or 
fast outputs.
Zone Number
Zone Name
Zone Type
Area Assignment
1
FRONT DOOR
EX
PERIM
2
BACK DOOR
EX
PERIM
3
GARAGE ENTRY DR
NT
INT
4
PATIO DOOR
EX
PERIM
5
BASEMENT DOOR
EX
PERIM
6
GARAGE DOOR
EX
PERIM
7
WAREHOUSE DOOR
EX
PERIM
8
SHIPPING DOOR
EX
PERIM
9
BREAKROOM DOOR
NT
INT
10
STOCKROOM DOOR
NT
INT
11
FRONT MOTION
NT
INT
12
BACK MOTION
NT
INT
13
HALLWAY MOTION
NT
INT
14
UPSTAIRS MOTION
NT
INT
15
BASEMENT MOTION
NT
INT
16
GARAGE MOTION
NT
INT
17
GLASSBREAK
NT
INT
18
WATER DETECTOR
AUX 1
INT
19
LOW TEMPERATURE
AUX 1
INT
20
SMOKE DETECTOR
FI
PERIM
21
FRONT SMOKE
FI
PERIM
22
BACK SMOKE
FI
PERIM
23
HALLWAY SMOKE
FI
PERIM
24
UPSTAIRS SMOKE
FI
PERIM
25
BASEMENT SMOKE
FI
PERIM
26
OFFICE SMOKE
FI
PERIM
27
WAREHOUSE SMOKE
FI
PERIM
BAD ZONES:
BYP
BYP  FORC  
REF
AUTO DIS  NO YES
ZONE INFORMATION
ZONE NO: -
ZONE INFORMATION