Digital Monitoring Products Inc PC0181 User Manual

Page of 58
XTLplus Installation and Programming Guide 
Digital Monitoring Products
27
BELL OPTIONS
29.5.3 Supervisory
Defines Bell Action for Supervisory Type Zones. The default is set at N.
29.5.4 Panic
Defines Bell Action for Panic Type Zones. The default is set at N.
29.5.5 Emergency
Defines Bell Action for Emergency Type Zones. The default is set at N.
29.5.6 
Auxiliary 1
Defines Bell Action for Auxiliary 1 Type Zones. The default is set at N.
29.5.7 
Auxiliary 2
Defines Bell Action for Auxiliary 2 Type Zones. The default is set at N.
Output Options
30.1 
Output Options
This section allows you to program output options for the 1116 and 1117 wireless 
outputs. Select from the following output numbers:
• 51 to 54
• 61 to 64
• F01 to F20 (To Activate Z-Wave Favorites)
30.2 
Communication Failure Output
This output/Favorite turns on when the panel fails to communicate with the 
receiver after three communication attempts. Enter 0 (zero) to disable this output.
Note: To turn off the Communication Failure Output, disarm the panel or turn the 
output off using the User Menu Outputs On/Off function.
30.3 
Fire Alarm Output
This output turns on any time a fire type zone is placed in alarm. The output turns 
off using the Sensor Reset option when no additional fire type zones are in alarm. 
Enter 0 (zero) to disable this output.
30.4 
Fire Trouble Output
This output/Favorite turns on any time a fire type zone is placed in trouble or 
when a supervisory type zone is placed in alarm or trouble. The output turns  
off when all fire and supervisory type zones restore to normal. Enter 0 (zero)  
to disable.
30.5 
Ambush Output
This output/Favorite turns on any time an Ambush code is entered at a keypad.
The output turns off using the Sensor Reset option. Enter 0 (zero) to disable  
this output.
30.6 
Begin Exit Output
This output/Favorite turns on any time an exit delay time starts. The output turns 
off when the system arms or when the arming has been stopped. Enter 0 (zero)  
to disable.
30.7 
End Exit Output
This output/Favorite turns on any time an exit delay time ends. The output turns 
off when the system disarms. Enter 0 (zero) to disable.
30.8 
Ready Output
This output/Favorite turns on whenever all disarmed zones are in a normal state. 
The output turns off when any disarmed zone is in a bad state. Enter 0 (zero)  
to disable.
30.9 
Armed Output
This output/Favorite turns on any time an area of the system is armed. The  
output turns off when the system completely disarms. Enter 0 (zero) to disable  
this output.
Favorites:
For a Home/Away system:
When the system is armed 
AWAY, the programmed Favorite activates.
When the system is armed 
SLEEP, the programmed Favorite plus 1 is activated.
SUPRVSRY TYPE:
N
PANIC  TYPE:
N
EMERGNCY TYPE:
N
AUXLRY 1  TYPE:
N
AUXLRY 2  TYPE:  N
OUTPUT OPTIONS
OUTPUT OPTIONS
COM FAIL OUT:
0
FIRE ALR OUT:
0
FIRE TRB OUT:
0
AMBUSH  OUT:
0
BEGIN EXIT: 0
END EXIT: 0
READY
OUT:
0
ARMED
OUT:
0