Digital Monitoring Products Inc PC0181 User Manual

Page of 58
XTLplus Installation and Programming Guide 
Digital Monitoring Products
37
ZONE INFORMATION
condition. The output can be activated regardless of the report to transmit 
or whether or not the zone is programmed as local. An output activated by a 
non-24-hour armed zone is turned off when the zone’s area is disarmed by a user.
To enter an Output Number, press any select key followed by the output number 
51-54, 61-64, or F1-F20. Press the COMMAND key.
33.11.3 
Output Action
Entering an Output Number displays this option that allows you to assign an output 
action. A description of the available output actions is given below:
STEADY - The output is turned on and remains on until the area is disarmed, an 
output cutoff time expires, or the output is reset from the keypad User Menu.
PULSE - The output alternates one second on and one second off until the area is 
disarmed, an output cutoff time expires, or the output is reset from the keypad 
User Menu.
MOMENTARY - The output is turned on only once for one second.
FOLLOW - The output is turned on and remains on while the zone is in an off 
normal, or bad condition. When the zone restores, the output is turned off.
After you have selected the Message To Transmit, the display prompts you for 
the same three selections for Disarmed Short, Armed Open, and Armed Short 
conditions. If the zone is a 24-hour type, only the Armed Open and Armed Short 
conditions are displayed. When you have programmed all of the zone conditions, 
the Swinger Bypass selection is then dis played.
33.12 
Swinger Bypass
Selecting YES allows the zone to be swinger bypassed by the panel according to  
the programming in Swinger Bypass Trips and Reset Swinger Bypass. The Bypassed 
zone displays in the keypad Status List. Selecting NO disables swinger bypassing for 
this zone.
How it works
If within one hour, a zone trips the total number of times as specified in Swinger 
Bypass Trips, the panel bypasses it until the following conditions occur; the area 
in which the zone is assigned is disarmed, the zone is manually reset through the 
Bypass Zones keypad User Menu function, the zone remains normal for one hour 
and the Reset Swinger Bypass is YES.
If the zone trips fewer than the specified times within one hour of the first trip, 
the bypass trip counter returns to 0 (zero) and the process must be repeated.
A report of the swinger bypass is sent to the receiver if Bypass Reports is YES.
33.13 
Prewarn Address
Option is only shown for an Exit zone.
At the start of the entry delay, all keypad addresses dis play ENTER CODE:-. If you 
want the prewarn to sound at all addresses, leave the default as shown.
To delete an address, press the matching number on the keypad. To disable 
prewarning at all keypads, press a top row key to clear the addresses shown. Press 
the COM MAND key when the address selection is com plete.
Note: The prewarn tone stops at the keypad when the first digit of a user code is 
entered. If, within five seconds, a valid user code is not entered or an invalid user 
code is entered, the prewarn tone begins sounding again. Fifteen seconds must 
elapse before entering a digit silences the prewarn tone again.
33.14 
Entry Delay
Option is only shown for an Exit zone. Select the entry delay timer for this  
zone. Entry delay timers 1 and 2 are programmed in Entry Delay in the System 
Options menu.
33.15 
Cross Zone
Select 
YES to enable cross-zoning for this zone. Cross-zoning requires this zone to 
trip twice, or this zone and another cross-zoned zone to trip, within a programmed 
time before an alarm report is sent to the receiver.
Note: To operate correctly, all cross-zone zones need to be programmed as the 
same zone type.
When a cross-zoned zone trips, the Output action assigned to the zone activates. 
See the Bell Action section. The cross-zone time specified in System Options begins 
to count down. See the Cross-Zone Time section. If another cross-zoned zone in the 
system faults, or if the first zone restores and faults again before the cross-zone time 
expires, the bell turns on and the panel sends an alarm report.
If no other cross-zoned zone in the system trips before the cross-zone time expires, 
ACTION:
STD PLS MOM  FOLW
SWGR BYP  NO  YES
PREWARN: 12345
ENTRY DELAY:
1
CRS ZONE  NO YES