UTC Fire & Security Americas Corporation Inc 680F-PIR User Manual

Page of 6
 
2 / 6 
 
PET Immune SAW PIR Motion Sensors Installation Sheet
 
• 
Mount the sensor permanently on a flat wall or in a 
corner. Do not set it on a shelf. 
• 
Windows should be closed in any area which has an 
armed motion sensor. 
• 
The sensor must be incline-mounted at a mounting 
height of 7.5 ft. See Figure 3. 
Figure 3: Wall Mount Options 
 
• 
Room temperature must be kept between 60° and 120°F 
(16° and 49° C). 
• 
Position the sensor so it faces a solid reference point, 
like a wall. 
Programming 
Refer to the panel documentation for information on 
programming the sensor into the panel. 
To Trip the Sensor 
1.  Set the panel to program mode. 
2.  Proceed to the Learn Sensors menu. 
3.  Remove the PIR from its mounting plate (activating the 
tamper switch). 
4.  Select the appropriate sensor group and number. 
5.  Exit the panel’s programming mode. 
6.  Return the PIR to its mounting plate. 
Final Testing 
Final testing should be done to verify radio signal integrity 
and confirm control panel programming and response. The 
actual transmitter range can be determined by performing a 
sensor test as follows: 
1.  With the PIR temporarily mounted at its intended 
location, remove the PIR from its mounting plate and 
activate the tamper switch to start the walk test mode. 
2.  Replace the sensor in its mounting plate. 
3.  Place the control panel in Sensor test mode. Move 
across the detection pattern until the sensor’s LED turns 
on. STOP your motion. 
4.  Listen for the appropriate system response. Refer to the 
specific panel installation manual for details on system 
response. If the system does not respond as expected, 
proceed to the “Troubleshooting” section. 
Mounting 
The sensors must be incline-mounted on a wall surface or 
incline-mounted in a corner at a mounting height of 7.5 ft. 
(2.5 m). 
To Mount the Sensor 
1.  Remove the mounting plate by depressing the button on 
the top of the sensor body. With the opposite hand pull 
the mounting plate away from the body of the sensor. 
Punch out the mounting holes that best fit your 
application. See Figure 3 for wall mount options. 
3.  See Figure 4 to determine which knockouts to use when 
mounting the motion sensor. Use the lower-side holes 
for corner mounting, or the lower-back holes for surface 
mounting. 
4.  If wall-tamper functionality is desired, remove the wall-
tamper knockout See Figure 4. 
Figure 4: PIR Mounting Plate Knockouts 
 
6.  Mark the location of the required holes on the mounting 
surface.