PET Immune SAW PIR Motion Sensors Installation Sheet
•
Mount the sensor permanently on a flat wall or in a
corner. Do not set it on a shelf.
corner. Do not set it on a shelf.
•
Windows should be closed in any area which has an
armed motion sensor.
armed motion sensor.
•
The sensor must be incline-mounted at a mounting
height of 7.5 ft. See Figure 3.
height of 7.5 ft. See Figure 3.
Figure 3: Wall Mount Options
•
Room temperature must be kept between 60° and 120°F
(16° and 49° C).
(16° and 49° C).
•
Position the sensor so it faces a solid reference point,
like a wall.
like a wall.
Programming
Refer to the panel documentation for information on
programming the sensor into the panel.
programming the sensor into the panel.
To Trip the Sensor
1. Set the panel to program mode.
2. Proceed to the Learn Sensors menu.
3. Remove the PIR from its mounting plate (activating the
tamper switch).
4. Select the appropriate sensor group and number.
5. Exit the panel’s programming mode.
6. Return the PIR to its mounting plate.
Final Testing
Final testing should be done to verify radio signal integrity
and confirm control panel programming and response. The
actual transmitter range can be determined by performing a
sensor test as follows:
and confirm control panel programming and response. The
actual transmitter range can be determined by performing a
sensor test as follows:
1. With the PIR temporarily mounted at its intended
location, remove the PIR from its mounting plate and
activate the tamper switch to start the walk test mode.
activate the tamper switch to start the walk test mode.
2. Replace the sensor in its mounting plate.
3. Place the control panel in Sensor test mode. Move
across the detection pattern until the sensor’s LED turns
on. STOP your motion.
on. STOP your motion.
4. Listen for the appropriate system response. Refer to the
specific panel installation manual for details on system
response. If the system does not respond as expected,
proceed to the “Troubleshooting” section.
response. If the system does not respond as expected,
proceed to the “Troubleshooting” section.
Mounting
The sensors must be incline-mounted on a wall surface or
incline-mounted in a corner at a mounting height of 7.5 ft.
(2.5 m).
incline-mounted in a corner at a mounting height of 7.5 ft.
(2.5 m).
To Mount the Sensor
1. Remove the mounting plate by depressing the button on
the top of the sensor body. With the opposite hand pull
the mounting plate away from the body of the sensor.
the mounting plate away from the body of the sensor.
2
Punch out the mounting holes that best fit your
application. See Figure 3 for wall mount options.
application. See Figure 3 for wall mount options.
3. See Figure 4 to determine which knockouts to use when
mounting the motion sensor. Use the lower-side holes
for corner mounting, or the lower-back holes for surface
mounting.
for corner mounting, or the lower-back holes for surface
mounting.
4. If wall-tamper functionality is desired, remove the wall-
tamper knockout See Figure 4.
Figure 4: PIR Mounting Plate Knockouts
6. Mark the location of the required holes on the mounting
surface.