UTC Fire & Security Americas Corporation Inc 801-IXT2 User Manual
Control Description
Enter
Press to select a particular menu item or commit to
panel memory a menu item that has just been
programmed.
panel memory a menu item that has just been
programmed.
Numeric keypad
Press the keys (0 to 9, *, and #) to enter access codes
or other numerical data.
or other numerical data.
*
Press to turn lights on.
#
Press to turn lights off.
Speaker
Provides voice output and sound key beeps
While the panel is idle, the text displays:
Display line 1
Arming level
Display line 2
HH:MMx (Time) and status icons
Arming and disarming
Table 2 below describes the arming levels that you can set
from the control panel.
from the control panel.
Table 2: Arming levels
Level Function
Description
0
Subdisarm
If your system includes 24-hour
protection sensors, you must
subdisarm the panel before accessing
these areas to avoid causing an alarm.
Environmental sensors (such as smoke
or carbon monoxide detectors) stay
active at all times.
protection sensors, you must
subdisarm the panel before accessing
these areas to avoid causing an alarm.
Environmental sensors (such as smoke
or carbon monoxide detectors) stay
active at all times.
1 Disarm
In
this
level,
only 24-hour sensors are
active.
2
Arm door and
window sensors –
exterior
window sensors –
exterior
This level arms the door and window
sensors, while leaving the interior
motion sensors disarmed.
sensors, while leaving the interior
motion sensors disarmed.
3
Arm motion sensors –
interior
interior
This level arms the interior motion
sensors, while leaving the exterior door
and window sensors disarmed.
sensors, while leaving the exterior door
and window sensors disarmed.
4 Arm
doors/windows
and motion sensors
This level arms all sensors.
To disarm (level 1):
1. Press
Disarm.
2. Enter your code when the displays shows Enter
Code
. The panel displays and speaks Disarmed, the
Disarm button lights up, and the panel beeps once.
To arm doors and windows (level 2):
1. Ensure that all doors and windows are closed.
2. Press
Doors+Windows.
3. Enter your code when the displays shows Enter
Code
, if a code is required. The panel displays Doors
+ Windows
, speaks Doors and Windows On, and the
Doors+Windows button lights up.
The panel starts an exit delay and sounds exit beeps in
groups of two until the exit delay expires.
groups of two until the exit delay expires.
To arm motion sensors (level 3):
1. Press
Motions.
2. Enter your code when the display shows Enter Code,
if a code is required. The display shows Motions,
speaks Motions On, and the Motions button lights.
speaks Motions On, and the Motions button lights.
The panel starts an exit delay and sounds exit beeps in
groups of three until the exit delay expires.
groups of three until the exit delay expires.
To arm doors, windows, and motion sensors (level 4):
1. Press
Doors+Windows.
2. Enter your code when the display shows Enter Code,
if a code is required.
3. While the panel is in the process of arming, press
Motions. The display shows Doors + Windows &
Motions
Motions
, speaks Doors and Windows On, Motions On,
and the Doors+Windows and Motions buttons light up.
The panel starts an exit delay and sounds exit beeps in
groups of four until the exit delay expires.
groups of four until the exit delay expires.
Silent exit
Press Silent after you arm the system to silence status
beeps. The silent exit feature silences the status beeps that
accompany the exit delay. The panel will still beep at the
beginning and end of the exit delay.
beeps. The silent exit feature silences the status beeps that
accompany the exit delay. The panel will still beep at the
beginning and end of the exit delay.
Note:
Enabling silent exit doubles the exit delay time.
Alarms
The system provides a series of alarms that indicate an
unusual occurrence. When an alarm is active, the display
shows Alarm Alarm Alarm, Press Status.
unusual occurrence. When an alarm is active, the display
shows Alarm Alarm Alarm, Press Status.
To cancel the alarm, enter a valid master or user code. After
alarms are canceled, the system will be disarmed.
alarms are canceled, the system will be disarmed.
System status
Press Status (no code is required) to cause the system to
display and speak the following types of information:
display and speak the following types of information:
• Alarm
conditions
• Alarm
history
• Trouble
conditions
2
Simon XT TableTop Quick Operation Guide