Intel i3-2328M FF8062701275100 Data Sheet

Product codes
FF8062701275100
Page of 170
Electrical Specifications
94
Datasheet, Volume 1
Notes:
1.
Refers to a component device that is not assembled in a board or socket and is not electrically connected to 
a voltage reference or I/O signal.
2.
Specified temperatures are not to exceed values based on data collected. Exceptions for surface mount 
reflow are specified by the applicable JEDEC standard. Non-adherence may affect processor reliability.
3.
T
absolute storage
 applies to the unassembled component only and does not apply to the shipping media, 
moisture barrier bags, or desiccant.
4.
Component product device storage temperature qualification methods may follow JESD22-A119 (low temp) 
and JESD22-A103 (high temp) standards when applicable for volatile memory.
5.
Intel branded products are specified and certified to meet the following temperature and humidity limits 
that are given as an example only (Non-Operating Temperature Limit: -40 °C to 70 °C and Humidity: 50% 
to 90%, non-condensing with a maximum wet bulb of 28 °C.) Post board attach storage temperature limits 
are not specified for non-Intel branded boards.
6.
The JEDEC J-JSTD-020 moisture level rating and associated handling practices apply to all moisture 
sensitive devices removed from the moisture barrier bag.
7.
Nominal temperature and humidity conditions and durations are given and tested within the constraints 
imposed by T
sustained storage 
and customer shelf life in applicable Intel boxes and bags.
7.9
DC Specifications
The processor DC specifications in this section are defined at the processor 
pins, unless noted otherwise.
 See 
• The DC specifications for the DDR3 signals are listed in 
Sideband and Test Access Port (TAP) are listed in 
 lists the DC specifications for the processor and are valid only while 
meeting specifications for junction temperature, clock frequency, and input 
voltages. Care should be taken to read all notes associated with each parameter. 
• AC tolerances for all DC rails include dynamic load currents at switching frequencies 
up to 1 MHz.
Table 7-4.
Storage Condition Ratings 
Symbol
Parameter
Min
Max
Notes
T
absolute storage
The non-operating device storage 
temperature. Damage (latent or otherwise) 
may occur when exceeded for any length of 
time.
-25 °C
125 °C
1, 2, 3, 4
T
sustained storage
The ambient storage temperature (in shipping 
media) for a sustained period of time
-5 °C
40 °C
5, 6
T
short term storage
The ambient storage temperature (in shipping 
media) for a short period of time.
-20 °C
85 °C
RH
sustained storage
The maximum device storage relative humidity 
for a sustained period of time.
60% at 24 °C
6, 7
Time
sustained storage
A prolonged or extended period of time; 
typically associated with customer shelf life.
0 Months
30 
Months
7
Time
short term storage
 
A short-period of time;
0 hours
72 hours