D9412GV2/D7412GV2 | Program Entry Guide | 3.0  RADXUSR1/RADXUSR2 
EN | 86 
 
 
Bosch Security Systems, Inc. | 10/08 | F01U003636-04 
 
U### Passcode 
U### User Group 
Default: 
Refer to the program record sheet 
Default: 
Blank 
Selection:  Three to six digits ( 0 to 9) 
Selection: 
Blank, 1 to 8 
Enter three to six digits to enable a pass code for the 
master user in this group. 
Create a group of up to 249 users (99 for the 
D7412GV2) whose combinations can be enabled and 
disabled using an automatic user window. This is the 
number entered into the W# User Group for any 
active W# User Window. Multiple windows can be 
programmed for one user group (up to eight) within 
one 24-hour period. For example, if User Group 1 
has a window running from 8:00 AM (start time) to 
4:00 PM (stop time), the users for that group can use 
their pass codes only between that time. Between 
4:00 PM that day and 8:00 AM the next day, the 
users cannot use their pass codes. 
 
 
To meet UL 864 requirements, enter at 
least one Passcode. 
 
 
User I.D.000 is the reserved user for 
service personnel. The default service 
pass code is 123. 
 
The programmer does not allow you to 
enter any pass code number that might 
conflict with a duress pass code. The 
programmer reserves the actual duress 
pass code and the duress pass-code 
number plus 1, duress pass-code number 
plus 2, duress pass code-number minus 
1, and duress pass-code number minus 
2.  
If Duress Type is set to 1, pass codes 
within a range of 1 for existing pass 
codes cannot be entered. If Duress Type 
is set to 2, pass codes within a range of 2 
cannot be entered. This rule applies even 
if duress is disabled. For example, with 
Duress Type set to 2, when a pass code 
of 654321 is entered, 654322, 654323, 
654320, and 654329 are reserved and 
are not available to other users. 
 
 
 
The authority to silence a bell is granted 
to all pass codes regardless of their 
authority level assignments. A user pass 
code can silence a Fire or Burg bell as 
long as any authority level is assigned to 
the area where the bell can be silenced. 
 
To enable this user’s pass code at all 
times, leave U### User Group blank. 
 
User Group Window times cannot be changed from 
the keypad. When a window is assigned to a user 
group, the users in that group rely on the window to 
be active (within the start and stop times) for their 
pass codes to function. The only way to disable the 
window is by reprogramming the control panel from 
the D5200 or remote programming software (RPS). 
U### Area 1 [through Area 8] Auth 
Default: 
Refer to the program record sheet 
Selection:  1 to 14 or Blank 
Assign an authority level to the user for this area. 
Blank means the user has no authority in this area. 
 
To meet UL 864 requirements, assign a 
valid authority level to the Passcode to 
silence bells.