D9412GV3/D7412GV3 | Program Entry Guide | 4.0  Schedules (Skeds) 
EN | 108 
 
 
Bosch Security Systems, Inc. | 10/11 | F01U170807-02 
 
Table 30: Programming for Two Same Day Opening Windows (refer to Figure 5
 
Open Close 
W# 
Day of Week 
Early 
Begin
 
Start
 
Stop 
Early 
Begin
 
Start
 
Stop 
eXcept On 
Holiday 
Holiday 
Index 
Area(s) 
S  M  T  W  T  F  S 
06: 00 
07 : 00 
08: 00 
 
 
 
Yes / No 
1   2   3   4 
1  2  3  4  5  6  7  8 
S  M  T  W  T  F  S 
13 : 00 
14 : 00 
15 : 00 
 
 
 
Yes / No 
1   2   3   4 
1  2  3  4  5  6  7  8 
 
Do not program a single window to cross the midnight boundary. The window stop time must be later than the 
window start time. To program a window that effectively crosses the midnight boundary, you must program two 
windows. 
For example, to program windows for an area that opens between 11:30 PM and 12:30 AM, five days a week, 
use two windows as shown in Table 31
Table 31: Programming to Link Two Days over Midnight
*
 
 
Open Close 
W# 
Day of Week 
Early 
Begin
 
Start
 
Stop 
Early 
Begin
 
Start
 
Stop 
eXcept On 
Holiday 
Holiday 
Index 
Area(s) 
S  M  T  W  T  F  S 
22 : 00 
23 : 30 
23 : 59 
 
 
 
Yes    No 
1   2   3   4 
 2  3  4  5  6  7  8 
S  M  T  W  T  F  S 
00 : 00 
00 : 00 
00 : 30 
 
 
 
Yes    No 
1   2   3   4 
 2  3  4  5  6  7  8 
 
* The setting for midnight is 00:00. 
W# Close Early Begin 
Default: 
00: 00 
Selection: 
HH:MM (hours and minutes) 
00:00 to 23:59 
Close Early Begin: This program item is one of 
three required to create a Closing Window. To finish 
programming a Closing Window, Close Window Start 
and Close Window Stop must be programmed. 
The time programmed in the Close Early Begin field 
is the earliest time the user can close an area before 
the Closing Window Start time. If Opening and 
Closing Reports are enabled, arming the area 
between midnight and the Close Early Begin time 
generates a Closing Report. Additionally: 
  If A# Disable O/C in Window is set to Yes and 
the area is armed between the Close Early Begin 
time and the Close Window Start time, the 
Closing Event is sent with an Early to Close 
modifier. If the Close Early Begin time is the 
same as the Close Window Start time, no Closing 
Event is sent. 
  If A# Disable O/C in Window is set to No and 
the area is armed at any time, a Closing Event is 
sent without the Early to Close or late to Close 
modifiers.  
Arming the area between the Close Window Start 
and Close Window Stop times creates a local event 
in the control panel event log, but does not send the 
Closing Report to the central station. 
Arming the area after the Close Window Stop time 
and before the next window’s Close Early Begin time 
(or midnight, whichever is earlier) generates a 
Closing Event with a Late to Close modifier. 
When configuring multiple windows to operate on the 
same day, ensure that they are added to the system 
in chronological order. For example, if three windows 
are programmed to execute on Tuesday, Window 1 
(W1) must occur before Window 2 (W2), and Window 
2 must occur before Window 3 (W3).  
 
Avoid programming the Open Early Begin 
time before a time that is between 
another window’s Open Window Start 
and Open Window Stop times. 
Disabled windows have a beginning time of 00:00. If 
the entry for this prompt is 00:00, but times are 
programmed for Close Window Start and Close 
Window Stop, the window is disabled. 
To disable the window, both the hours and minutes 
spaces must be 00:00. 
00:00 is midnight, 23:59 is 11:59 PM. Make entries 
using a 24-hour clock (for example, 7:00 AM is 
entered as 07:00, 2:45 PM is entered as 14:45).