To Convert Surface Burners
1. Remove Natural gas orifice hoods. Locate the LP gas orifice 
hoods from the package attached to the outer plenum area of 
this appliance.
2. To convert from Natural gas to LP gas, apply a ½" open-end 
wrench to hex section of orifice hood. Turn counterclockwise 
to remove.
3. Replace with correct color-coded orifice hoods (supplied). 
See the “LP Gas Orifice Hood Chart.” Turn clockwise to 
install. Screw down the orifice hood so that the outer end of 
the orifice hood is 
¹¹⁄₁₆" from the face of the mounting spud. 
See the following illustration.
LP Gas Orifice Hood Chart
4. Place Natural gas orifice in plastic parts bag for future use 
and keep with package containing literature.
5. Repeat for the remaining burners.
Complete Installation
1. Refer to the “Make Gas Connection” section for properly 
connecting the cooktop to the gas supply.
2. Refer to the “Burner Ignition” section for proper burner 
ignition, operation, and burner flame adjustments.
IMPORTANT: You may have to adjust the “LO” setting for 
each cooktop burner.
Checking for proper cooktop burner flame is very important. 
The cooktop “low” burner flame should be a steady blue 
flame approximately ¼" (0.64 cm) high.
3. Refer to the “Complete Installation” section of this manual to 
complete this procedure. 
Natural Gas Conversion
1. Turn manual shutoff valve to the closed position.
2. Unplug cooktop or disconnect power.
To Convert Gas Pressure Regulator
1. Remove the access cap by using a wrench, turning the 
access cap counterclockwise.
2. Remove spring retainer from the cap by pushing against the 
flat side of the spring retainer. Look at the spring retainer to 
locate the “LP” or “NAT” position. Turn over the spring 
retainer so the “NAT” is showing on the bottom. Snap the 
spring retainer back into the cap. Reinstall the cap onto the 
regulator.
3. Test the gas pressure regulator and gas supply line.
The regulator must be checked at a minimum 1" (2.5 cm) 
water column above the set pressure. The inlet pressure to 
the regulator should be as follows for operation and checking 
the regulator setting:
Natural Gas:
Minimum pressure: 6" (15.2 cm) WCP
Maximum pressure: 14" (35.5 cm) WCP
Gas Supply Pressure Testing
Gas supply pressure for testing regulator must be at least 
1" water column pressure above the manifold pressure 
shown on the model/serial rating plate.
Line pressure testing above ½ psi gauge (14" WCP)
The cooktop and its individual shutoff valve must be 
disconnected from the gas supply piping system during any 
pressure testing of that system at test pressures in excess of 
½ psi (3.5 kPa).
Line pressure testing at ½ psi gauge (14" WCP) or lower
The cooktop must be isolated from the gas supply piping 
system by closing its individual manual shutoff valve during 
any pressure testing of the gas supply piping system at test 
pressures equal to or less than ½ psi (3.5 kPa).
A. ½" open-end wrench
B. Orifice hood
C. Mounting spud
Burner
BTU/hr
Orifice
Diameter 
(inches)
Color
Left rear
7,500
#66
.033
Zinc
Left front
7,500
#66
.033
Zinc
Center rear
6,500
#68
.031
Red
Center front
9,000
#63
.037
Blue
Right rear
6,500
#68
.031
Red
Right front
9,000
#63
.037
Blue
Turn
clockwise
to tighten
Turn 
counterclockwise
to remove
A
B
C
A. To cooktop
B. Shutoff valve (closed position)
C. Gas supply line
A. Access cap
B. Gasket
C. Gas pressure regulator
D. NAT position
E. LP position
A
B
C
A
B
C
D
E