Jenn-Air W10526003A User Manual

Page of 28
14
To Convert Surface Burners
1. Remove LP gas orifice hoods. Locate the Natural gas orifice 
hoods that were originally installed on the cooktop.
2. To convert from LP gas to Natural gas, apply a ½" open-end 
wrench to hex section of orifice hood. Turn counterclockwise 
to remove.
3. Replace with correct color-coded orifice hoods (supplied). 
See the “Natural Gas Orifice Hood Chart.” Turn clockwise to 
install. Screw down the orifice hood so that the outer end of 
the orifice hood is 
¹¹⁄₁₆" from the face of the mounting spud. 
See the following illustration
.
Natural Gas Orifice Hood Chart
4. Place LP gas orifice in plastic parts bag for future use and 
keep with package containing literature.
5. Repeat for the remaining burners.
Complete Installation
1. Refer to the “Make Gas Connection” section for properly 
connecting the cooktop to the gas supply.
2. Refer to the “Burner Ignition” section for proper burner 
ignition, operation, and burner flame adjustments.
IMPORTANT: You may have to adjust the “LO” setting for 
each cooktop burner.
Checking for proper cooktop burner flame is very important. 
The cooktop “low” burner flame should be a steady blue 
flame approximately ¼" (0.64 cm) high.
3. Refer to the “Complete Installation” section of this manual to 
complete this procedure. 
A. ½" open-end wrench
B. Orifice hood
C. Mounting spud
Turn
clockwise
to tighten
Turn 
counterclockwise
to remove
A
B
C
Burner
BTU/hr
Orifice
Diameter 
(inches)
Color
Left rear
8,000
#55
.0520
Green
Left front
8,000
#55
.0520
Green
Center rear
10,000
#53
.0595
Brass
Center front
10,000
#53
.0595
Brass
Right rear
10,000
#53
.0595
Brass
Right front
10,000
#53
.0595
Brass