Output Commands 
68 
Series N5700 User’s Guide  
Output Commands 
Output commands enable the output, power-on, and protection 
functions. 
OUTPut[:STATe] <Bool> 
OUTPut[:STATe]? 
This command enables or disables the specified output(s). The 
enabled state is On (1); the disabled state is Off (0). The state of a 
disabled output is a condition of zero output voltage and a zero 
source current (see *RST). The query returns 0 if the output is off, 
and 1 if the output is on. The *RST value = Off. 
OUTPut:PON:STATe RST|AUTO 
OUTPut:PON:STATe? 
This command determines if the power-on state will be determined 
by the reset state, or the settings the unit had when it was turned off. 
RST programs the unit to the reset state; AUTO programs the unit to 
the settings it had when it was turned off. The power-on state 
information is saved on non-volatile memory. 
Refer to *RST and *RCL under System Commands for details. 
OUTPut:PROTection:CLEar 
This command clears the latched signals that have disabled the 
output. The over-voltage and over-current conditions are always 
latching. The over-temperature condition, AC-fail condition, Enable 
pins, and SO pins are latching if OUTPut:PON:STATe is RST, and non-
latching if  OUTPut:PON:STATe is AUTO. 
All conditions that generate the fault must be removed before the 
latch can be cleared. The output is then restored to the state it was in 
before the fault condition occurred.