section 2 – operation
recreational vehicle generator
Figure 2.2 – Low Oil Pressure and  
High Temperature Switches
High Temperature Switch
Low Oil Pressure
Switch
2.8.3  FIeld boost
The  Controller  Circuit  Board  houses  a  field  boost 
diode and resistor that are not part of the automatic 
choke  circuit.  These  two  components  are  part  of 
a  “field  boost”  circuit  (Figure  2.3).  During  engine 
cranking  only,  a  positive  DC  (battery)  voltage  is 
delivered  through  the  diode,  resistor,  brushes  and 
slip rings, to the generator rotor. Application of this 
voltage to the rotor “flashes the field” whenever it is 
started. Flashing of the field each time the generator 
starts makes sure that a sufficiently strong magnetic 
field  is  available  to  produce  “pickup”  voltage  in  the 
stator windings.
Figure 2.3 – Field Boost Circuit
2.8.4  overvoltage protectIon
A  solid-state  voltage  regulator  (Figure  2.4)  controls 
the generator’s AC output voltage. This regulator sup-
plies an excitation current to the rotor. By regulating 
the rotor’s excitation current, the strength of its mag-
netic field is regulated and, in turn, the voltage deliv-
ered to connected electrical loads is controlled. When 
the AC frequency is 60 Hertz, voltage is regulated at 
120 volts (voltage-to-frequency ratio is 2-to-1).
Figure 2.4 – Solid State Voltage Regulator
The  voltage  regulator  also  incorporates  a  “voltage 
surge protection circuit.” This circuit prevents trou-
blesome  surges  in  the  generator  AC  output  voltage. 
Voltage surge is a common cause of damage to elec-
tronic equipment.
2.9   addItIonal InForMatIon
2.9.1  25-hour break-In perIod
The first 25 hours of operation is the break-in period 
for  the  generator.  Properly  breaking  in  the  genera-
tor  is  essential  to  minimize  fuel  consumption  and 
provide  maximum  engine  performance.  During  this 
25-hour break-in period, follow this procedure:
•  Run the unit at varying electrical loads to help seat 
the engine piston rings properly.
•  Check  the  engine  oil  level  frequently.  Add  oil  if 
needed.  It  is  normal  for  the  generator  engine  to 
consume more oil than is normal until the piston 
rings have properly seated.
•  For  the  75-hour  operation  following  the  break-in 
period,  avoid  light  electrical  loads.  Load  the  gen-
erator  at  50  percent  (or  more)  of  its  rated  watt-
age capacity. Repeated light loads during these 75 
hours can cause improper seating of engine piston 
rings,  resulting  in  blowby  and  high  oil  consump-
tion.
•  After operating the unit for 25 hours, complete the 
tasks recommended under Section 2.10.2.
2.9.2  25-hour check-up
After  the  25-hour  break-in  period,  contact  an 
Authorized  Service  Dealer  for  the  following  main-
tenance.  The  vehicle  owner  is  responsible  for  any 
charges:
•  Change the engine crankcase oil and oil filter.
•  Check the oil level.
•  Inspect the cooling and ventilation openings.
•  Check the engine carburetor adjustments.
•  Check the engine ignition system.
•  Inspect the entire electrical system.
•  Inspect the engine exhaust system.