Guardian Technologies 004701-0 Manual De Usuario

Descargar
Página de 52
 
section 3 – Maintenance
recreational vehicle generator
•  Change the engine 
oil filter after the first 25 hours 
of operation, and every 100 operating hours there-
after.
To  change  the  oil  and/or  oil  filter,  proceed  as  
follows (see Figure 3.1): 
1.  Run the engine until it is thoroughly warmed up 
(at least five minutes) then shut OFF the engine.
2.  Immediately after the engine shuts OFF, pull the 
oil drain cover free of the base. Remove the plug 
from the tube with a 5/16” allen wrench and drain 
the oil into a suitable container. Loosening the oil 
fill cap will allow the crankcase to drain faster.
3.  After  the  oil  has  drained,  replace  the  plug  onto 
the end of the oil drain tube. Retain the cover in 
the base. 
4.  With the oil drained, remove the old oil filter by 
turning it counterclockwise. Place a towel under-
neath to catch excess oil.
5.  Apply a light coating of clean engine oil to the gas-
ket of the new filter. Fill the filter until saturated 
with clean oil.
6.  Screw the new filter on by hand until its gasket 
lightly contacts the oil filter adapter. Then, tighten 
the filter an additional 3/4 to one turn.
7.  Remove the dipstick and wipe it dry with a clean, 
lint-free cloth. This will be used later to check the 
oil level.
8.  Remove  the  oil  fill  cap  on  the  oil  fill  tube  and 
slowly add the proper type and amount of recom-
mended  oil  (see  Section  1.5.4).  Periodically  use 
the dipstick to check the oil level and continue to 
fill the crankcase until the oil reaches the dipstick 
“Full” mark. DO NOT FILL ABOVE THE “FULL” 
MARK.
9.  Install and tighten the oil fill cap and the dipstick 
before operating the engine.
10. Start the engine and check for leaks.
NOTE:
Check  the  oil  level  and  fill  to  the  “FuLL”  mark 
after checking for leaks. The filter will retain some 
oil.
3.3    MaIntaInIng the engIne  
aIr cleaner
3.3.1  cleanIng the FoaM precleaner
Clean  and  re-oil  the  foam  precleaner  every  three 
months  or  every  25  hours  of  operation,  whichever 
occurs  first.  Service  the  foam  precleaner  more  fre-
quently if operating the generator in extremely dusty 
or  dirty  conditions.  Use  the  following  procedure 
(Figure 3.2):
1.  Turn the two screws counterclockwise to loosen.
2.  Remove the cover, foam precleaner and paper filter.
3.  Remove the foam precleaner from the cover.
4.  Wash the foam precleaner in liquid detergent and 
water.
5.  Wrap  the  foam  precleaner  in  a  clean  cloth  and 
gently squeeze it dry.
6.  Saturate  the  foam  precleaner  in  clean  engine 
oil. Gently squeeze it in a clean cloth to remove 
excess oil and to distribute oil (DO NOT TWIST).
7.  Install  the  foam  precleaner  into  the  cover,  fol-
lowed by the paper filter.
8.  Install the cover, foam precleaner and paper filter.
9.  Tighten the two screws to retain the filter in place.
Figure 3.2 – Engine Air Cleaner
3.3.2   cleanIng or replacIng the paper 
FIlter
Once  each  year  or  every  100  hours  of  operation 
(whichever  comes  first),  clean  or  replace  the  paper 
filter.  The  new  replacement  filter  must  be  flame 
retardant. Service the paper filter more frequently if 
operating  the  generator  in  extremely  dusty  or  dirty 
conditions. Use the following procedure (Figure 3.2):
1.  Follow  steps  1-3  in  Section  3.3.1;  service  the 
foam precleaner if necessary.
2.  Remove the paper filter.
3.  Clean the air filter by tapping it gently on a solid 
surface. If the filter is too dirty, replace it with a 
new one. Dispose of the old filter properly.
4.  Clean  the  air  cleaner  cover  then  reassemble  
following steps 7-9 in Section 3.3.1.
3.4   clean aIr Intake
Clean all foreign material from the air intake (Figure 
3.3) at least once every 100 hours of operation. Clean 
more often if necessary.
Inspect the area around the generator exhaust muf-
fler  periodically  and  remove  all  grass,  leaves,  dirt, 
etc., from this area.