section 3 – Maintenance
recreational vehicle generator
 0
2.9.3   attentIon requIred aFter  
subMersIon
If  the  recreational  vehicle  generator  has  been  sub-
merged in water, it 
MuST NOT be started and oper-
ated.  Following  any  submersion  in  water,  have  an 
Authorized Service Dealer thoroughly clean and dry 
the generator.
2.9.4   operatIon In hIgh grass orbrush
Never  operate  the  generator  while  the  vehicle  is 
parked over high grass, weeds, brush, leaves or any 
other  combustible  substance.  Such  materials  can 
ignite and burn from the heat of the exhaust system. 
The  generator  exhaust  system  becomes  extremely 
hot during operation and remains hot for a long time 
after it has shut down.
2.9.5  eFFects oF MoIsture and dIrt
Keep the generator set as clean and dry as possible.  
Protect  the  unit  against  excessive  dust,  dirt,  cor-
rosive  vapors,  road  splash,  etc.  Permitting  dirt  and 
moisture  to  accumulate  on  generator  windings  will 
have an adverse effect on the insulation resistance of 
those windings.
When moisture is allowed to remain in contact with 
windings,  some  of  the  moisture  will  be  retained  in 
voids  and  cracks  in  the  insulation.  This  causes  a 
reduced  insulation  resistance  and  will  eventually 
cause problems. Dirt will make the problem worse, 
since  dirt  tends  to  hold  moisture  in  contact  with 
windings. Salt (as from sea air) also will worsen the 
problem since it tends to absorb moisture from the 
air. Salt and moisture, when combined, form a good 
electrical conductor.
3.1   checkIng the engIne oIl 
level
For  oil  capacities  and  requirements,  see  “Engine 
Oil  Requirements,”  Section  1.5.4.  Check  the  engine 
crankcase oil level at least every eight hours of opera-
tion, or before using it. To check the engine oil level, 
proceed as follows (see Figure 3.1):
1.  Be sure the generator is as level as possible.
2.  Remove the dipstick and wipe it dry with a clean, 
lint-free cloth.
3.  Install and tighten the dipstick cap; then, remove 
it  again.  The  oil  level  should  be  at  the  dipstick 
“Full” mark.
4.  If necessary, remove the oil fill cap on the rocker 
cover and slowly add oil until it reaches the dip-
stick  “Full”  mark.  DO  NOT  FILL  ABOVE  THE 
“FULL” MARK.
  Never operate the engine with the oil level 
below the “Add” mark on the dipstick. Doing 
this could damage the engine.
5.  Install and tighten the oil fill cap and the dipstick 
before operating the engine.
3.2    changIng the engIne oIl 
and/or oIl FIlter
•  Change  the 
engine  oil  after  the  first  25  hours 
of  operation  (after  the  25-hour  break-in  peri-
od,  see  Section  2.10.1).  Thereafter,  change  the  
oil every 100 operating hours. Change the oil more 
frequently  if  operating  consistently  under  heavy 
load or at high ambient temperatures.
GENERAC OHVI INDUSTRIAL ENGINE
I
t
r
e ,
e
h it
w a
n c .-
s
m
, I
e
W
POWERED
W
y s
S
r
o
P
w e
A C
N
R
E
G E
OHVI
t
GENERAC
TM
RV SERVICE LOCATOR:
.00..
QUIETPACT 0G
*
S E R V IC E A C C E S S
P A N E L
OIL LEVEL:
CHECK DAILY
AIR FILTER:
CLEAN PREFILTER
EVERY 100 HOURS.
REPLACE ELEMENT
EVERY 250 HOURS.
OIL & OIL FILTER:
CHANGE EVERY 100
(IF NECESSARY)
EVERY 500 HOURS.
HOURS. REPLACE PLUGS
PLUGS EVERY 100
INSPECT & CLEAN
SPARK PLUGS:
REPLACEMENT INFORMATION
*
PERFORM MORE OFTEN IN DUSTY CONDITIONS
AIR FILTER LOCATED BEHIND PANEL.
MAINTENANCE SCHEDULE
AIR FILTER P/N:
0D3262
070185
OIL FILTER P/N:
SPARK PLUG P/N:
072347
OIL CAPACITY WITH FILTER:
0.8L/0.84QT
TEMPERATURE
SAE VISCOSITY
32˚F AND HIGHER
10˚F TO 100˚F
0˚F TO 80˚F
-20˚F TO 50˚F
5W-30
10W-30
15W-40
30
WHEN SERVICE OR PARTS ARE NEEDED IN
THE USA OR CANADA, CONTACT THE GENERAC
SERVICE LOCATOR AT 1-800-333-1322.
HOURS. (OR ANNUALLY)
PREFILTER P/N:
0D4511
FUEL FILTER P/N:
0D7515
FUEL FILTER:
CHANGE EVERY 400
HOURS. (OR ANNUALLY)
*
*
P R I M E
F U E L
S T O P
S T A R T
3 0 A
C . B .
A
F U S E
CONTROL CENTER
7.5
To Rem
ov
e
Oil Dipstick/Oil Fill
Oil Drain
Oil Filter
Figure 3.1 – Oil Maintenance Features