If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely,
contact the Lincoln Electric Service Department for technical troubleshooting assistance before you proceed.
Call 1-888-935-3878.
CAUTION
TROUBLESHOOTING AND REPAIR
F-4
F-4
VRTEX 
TM
360
POWER-UP PROBLEMS
Observe Safety Guidelines detailed in the beginning of this manual.
PROBLEMS
(SYMPTOMS)
POSSIBLE AREAS OF
MISADJUSTMENT(S)
RECOMMENDED
COURSE OF ACTION
The VRTEX
TM
360 does not turn
on when the On Switch is pushed.
The green indicator light does not
light.
Make certain the correct input
voltage is being applied to the
VRTEX
TM
360.    (115-230VAC
single phase).
Check input circuit breakers.
Reset if tripped.
Check the input cord for loose
or  faulty  connections  at  the
machine and at the plug.
Check  for  the  correct  input
voltage at leads #101 to #102.
These checks can be made at
the input circuit breakers and
also  at  the  Upper  (AC)
Terminal Block.  See the wiring
diagram.
If the correct volt is not present
check the continuity of leads
#101 and #102.  
If the correct volt is present at
the Upper (AC) Terminal Block
(leads #101 to #102) check the
functionality of the ON Switch.
If  the  switch  is  functioning
correctly  the  input  voltage
should be present from lead
#103A to lead #102 when the
switch  is  pushed  and  held
closed.    See  the  wiring
diagram.
If the correct volt is present at
the Upper (AC) Terminal Block
(leads #101 to #102) check the
functionality of the ON Switch.
If  the  switch  is  functioning
correctly  the  input  voltage
should be present from lead
#103A to lead #102 when the
switch  is  pushed  and  held
closed.    See  the  wiring
diagram.
Make  sure  the  CPU  power
switch is in the ON position.
If the correct input voltage is
present at lead #103A to lead
#102 check to make sure it is
being applied to the CPU.  See
the wiring diagram.