Lincoln Electric SVM200-A Manual De Usuario

Descargar
Página de 171
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely,
contact the Lincoln Electric Service Department for technical troubleshooting assistance before you proceed.
Call 1-888-935-3878.
CAUTION
TROUBLESHOOTING AND REPAIR
F-6
F-6
VRTEX 
TM
360
POWER-UP PROBLEMS
Observe Safety Guidelines detailed in the beginning of this manual.
PROBLEMS
(SYMPTOMS)
POSSIBLE AREAS OF
MISADJUSTMENT(S)
RECOMMENDED
COURSE OF ACTION
The  VRTEX
TM
360  does  not
power up when the ON Switch is
pushed.  The green indicator light
does come on and stays on.
The green light indicates that
the CPU Computer Assembly is
receiving  input  power  and
activating the green light via a
USB cable.
Verify that the green LEDs on
the 5VDC Power Supply and
the 12VDC Power Supply are
on.    If  they  are  not,  then
perform  the  5VDC  Power
Supply  Test
and the 12VDC
Carefully  check  the  input
voltage being applied to the
Monitor at leads #103 to #102.
It should be the same as the
input line voltage. (115-230VAC
single phase).  See the wiring
diagram.
If the above checks are OK
then check for broken cables
and loose connections between
the  CPU  and  the  User
Interface, the 12VDC Supply
and the Relay PC Board and
the  VGA  Splitter,  the  5VDC
supply and the FMD Control
Unit,  and  the  Polhemus
Interface  Module.    See  the
wiring diagram.