POWER-UP PROBLEMS
Observe Safety Guidelines detailed in the beginning of this manual.
PROBLEMS
(SYMPTOMS)
POSSIBLE AREAS OF
MISADJUSTMENT(S)
RECOMMENDED
COURSE OF ACTION
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely,
contact the Lincoln Electric Service Department for technical troubleshooting assistance before you proceed.
Call 1-888-935-3878.
CAUTION
(Continued)
If the correct input voltage is
being applied to the CPU and
the VRTEX
TM
360 does not
power-up the CPU may be
faulty.
TROUBLESHOOTING AND REPAIR
F-5
F-5
VRTEX 
TM
360
The  VRTEX
TM
360  does  not
power up when the ON Switch is
pushed.  The green indicator light
does come on but does NOT stay
on  when  the  ON  Switch  is
released.
Make certain the correct input
voltage is being applied to the
VRTEX
TM
360.    (115-230VAC
single phase).
With the ON Switch activated
5VDC should be present at the
Input Relay Coil.  Terminal A1
(Red  Lead)  to  Terminal  A2
(Black Lead).  See the wiring
diagram.  If the green indicator
light is on the 5VDC should be
present at the relay coil.
Check  for  loose  or  faulty
connections between the Input
Relay,  the  Upper  Terminal
Block  and  the  ON  Switch.
Check leads 101A and 103A.
See the wiring diagram.
If the 5VDC is being applied to
the Input Relay Coil and the
above mentioned connections
and  leads  are  OK  the  Input
Relay  Coil  may  be  faulty.
Replace.
If the 5VDC is not present at
Terminals A1 to A2 check for
loose  or  faulty  connections
between the Input Relay Coil
and the CPU USB port.  See
the wiring diagram.  
The CPU may be faulty.