Cisco Systems 7500 Series Manual De Usuario

Descargar
Página de 303
7-10
Cisco 7500 Series Installation and Configuration Guide
OL-5008-03 B0
Chapter 7      Maintaining Your Cisco 7513, Cisco 7513-MX, and Cisco 7576 Router
  Maintenance Procedures for the Cisco 7513, Cisco 7513-MX, and Cisco 7576
Removing and Replacing the Cisco 7513, Cisco 7513-MX, and Cisco 7576 Blower 
Module
In the Cisco 7513, Cisco 7513-MX, and Cisco 7576, the blower provides cooling air to the internal 
system components. When you view the chassis from the noninterface processor end, the blower module 
is located above the card cage. (See 
.) Two slotted captive screws hold the blower module in 
place. The front panel LEDs are located on a printed circuit board inside the blower module. If one of 
these LEDs fails, the blower module must be replaced. The LED board inside the blower module 
assembly is not separately replaceable.
Warning
Although the system should not be operating when you remove the blower module, it is not necessary 
to turn OFF system power before removing the blower module. However, with the system power ON 
and the blower module removed, high current is exposed on the blower module power connector at 
the backplane; do not
 insert conductive items into the empty blower module opening. After an 
operating blower module is removed, the blower impeller blades will continue to spin for 
approximately two minutes; do not
 insert anything into the module’s vent holes while the impeller is 
spinning. 
Caution
With chassis power on and the blower module removed, no cooling air is circulating through the system. 
Replace the blower module before the system overheats. The system will shut down approximately 2 
minutes after reaching the shutdown temperature threshold.
Use the following procedure to remove and replace the blower module:
Step 1
Loosen the captive screws that fasten each end of the blower module using a flat-blade screwdriver. (See 
Step 2
Grasp the handle on the front of the module and slowly pull it straight out of the chassis. (See 
Step 3
Replace the blower module. Using both hands to handle the module, and with the intake vents on the 
blower module facing down and the “Insert This Side Up” label facing up, insert the module into the 
chassis opening. Keep the module as straight as possible as you guide it into the chassis. 
Figure 7-8
Removing the Cisco 7513, Cisco 7513-MX, and Cisco 7576 Blower Module
H3038
Captive installation screws (2)
Blower module