Cisco Aironet 1300 Series Lightweight Outdoor Access Point Mounting Instructions
78-17634-01
Mounting the Access Point
Two short sub-mini RG-59 coax cables (12 in.)
Tighten the bolts to secure the power injector to the access point. Torque bolts to 6 to 8 ft-lbs.
Connecting the Cables 
This procedure explains how to connect the cables and how to ground the access point: 
Step 1
Connect the two short coax cables to the power injector and to the access point. 
Caution
To prevent damage to the access point or power injector, connect all coax cables from the 
power injector to the access point and connect the power jack to the power injector before 
applying power.
Step 2
Find the building's grounding electrode system and then connect the access point ground lug to it using 
6 AWG copper wire. Use a crimping tool to crimp the wire to the ground lug. For more information about 
attaching the ground lug to the access point, see 
 in th
. See 
 for the ground lug location.
Warning
This equipment must be grounded. Never defeat the ground conductor or operate the equipment in the 
absence of a suitably installed ground conductor. Contact the appropriate electrical inspection 
authority or an electrician if you are uncertain that suitable grounding is available.
 Statement 1024
Note
The grounding block and grounding wire are not required when mounting both the access point 
and the antenna in a sheltered indoor environment.
Rooftop or Wall Mount
The mounting kit has a rooftop mounting bracket that is suitable for flat roofs, sloping roofs, and outdoor 
walls. Mounting the access point on a rooftop or wall includes the following subtasks:
1.
Mounting the access point
2.
Routing the cables
This warning applies to outdoor installations.
Warning
Only trained and qualified personnel should be allowed to install, replace, or service this equipment. 
Statement 1030