HP proliant dl580 Manual De Usuario

Descargar
Página de 104
 
Removal and replacement procedures  50 
4.
 
Install the replacement fan. 
 
5.
 
Repeat to replace additional fans as needed. 
6.
 
Observe the LED on each installed fan to be sure it is illuminated green ("
7.
 
Observe the internal system health LED on the front panel to be sure it is illuminated green ("
  NOTE:  If the front panel internal system health LED is not green after you install hot-plug fans, reseat the hot-
plug fan or refer to the troubleshooting section. 
 
Memory overview 
This server supports up to four memory boards. Each memory board contains four DIMM slots for a total 
of 16 DIMM slots in the server. Memory can be expanded by installing PC2-3200R Registered DDR2 
DRAM DIMMs. 
The server supports a host of AMP options to optimize server availability: 
 
 
Online spare memory (on page 
 
Hot-plug mirrored memory (dual- and quad-board) ("
 
Hot-plug RAID memory (on page 
Hot-plug operations can be hot-add or hot-replace. Hot-add makes additional memory resources available 
to the operating system. Hot-replace allows failed or degraded DIMMs to be replaced while the server is 
running. 
The maximum supported total memory for this server is 64 GB using four memory boards. The maximum 
supported memory per memory board is 16 GB using four 4-GB DIMMs. 
For an overview of single- and dual-rank DIMMs, refer to "Single- and dual-rank DIMMs (on page 
For DIMM slot locations and bank assignments, refer to "DIMM slot locations (on page 
 
General memory configuration requirements 
The following configuration requirements apply regardless of the AMP mode.