HP proliant dl580 Manual De Usuario

Descargar
Página de 104
 
Removal and replacement procedures  49 
3.
 
Remove the hot-plug power supply from the server. 
 
  CAUTION:  To prevent improper cooling and thermal damage, do not operate the server unless all bays 
are populated with either a component or a blank.  
To replace the component, reverse the removal procedure. 
 
Replacing hot-plug fans 
The server supports redundant hot-plug fans ("
) to provide proper airflow to the 
server if a primary fan fails. 
  WARNING:  To prevent personal injury from hazardous energy: 
  Remove watches, rings, or other metal objects. 
  Use tools with insulated handles. 
  Do not place tools or metal parts on top of batteries. 
  IMPORTANT:  Remove and replace one fan at a time. If the system detects two fan failures in the same 
zone, the server shuts down to avoid thermal damage. 
1.
 
Extend the server from the rack, if applicable ("
2.
 
Remove the access panel ("
3.
 
Remove the malfunctioning hot-plug fan from the server.