DMC-1700/1800 
Chapter 3 Connecting Hardware  •  45 
All motion programs that are currently running are terminated when a transition in the Abort input is detected.  For 
information on setting the Off-On-Error function, see the Command Reference, OE. 
Uncommitted Digital Inputs 
The DMC-1700/1800 has 8 opto-isolated inputs. These inputs can be read individually using the function @ IN[x] 
where x specifies the input number (1 thru 8).  These inputs are uncommitted and can allow the user to create 
conditional statements related to events external to the controller.  For example, the user may wish to have the x-axis 
motor move 1000 counts in the positive direction when the logic state of IN1 goes high
1X80  
Controllers with more than 4 axes have 16 optoisolated inputs and 8 TTL inputs which are denoted as 
Inputs 1 thru 24. 
For controllers with more than 4 axes, the inputs 9-16 and the limit switch inputs for the additional 
axes are accessed through the second 100-pin connector. 
  IN9-IN16 
INCOM 
FLE,RLE,HOMEE 
FLF,RLF,HOMEF 
FLG,RLG,HOMEG 
FLH,RLH,HOMEH 
LSCOM 
This can be accomplished by connecting a voltage in the range of +5V to +28V into INCOM of the input circuitry  
from a separate power supply
  17X8 
 
DMC-1718, 1728, 1738, 1748 controllers have 64 additional TTL I/O.  The CO commands configures 
each set of 8 I/O as inputs or outputs.  The DMC-17X8 use two 50 pin headers which connect directly 
via ribbon cable to an OPTO 22 (24 I/O) or Grayhill Opto rack (32 I/O). 
The function “@IN[n]” (where n is 1-80) can be used to check the state of the inputs 1 thru 80. 
Wiring the Optoisolated Inputs 
Bi-Directional Capability. 
All inputs can be used as active high or low - If you are using an isolated power supply you can connect +5V to 
INCOM or supply the isolated ground to INCOM.  Connecting +5V to INCOM configures the inputs for active 
low.  Connecting ground to INCOM configures the inputs for active high. 
INCOM can be located on the DMC-1700/1800 directly or on the ICM-1900 or AMP-19X0.  The jumper is  
labeled INCOM.
 
The optoisolated inputs are configured into groups.  For example,  the general inputs, IN1-IN8, and the 
ABORT input are one group.  Figure 3.1 illustrates the internal circuitry.  The INCOM signal is a common 
connection for all of the inputs in this group.  
The optoisolated inputs are connected in the following groups  
 
Group (Controllers with 1- 4 Axes) 
Group (Controllers with 5 - 8 Axes) 
Common 
Signal 
IN1-IN8, ABORT 
IN1-IN16, ABORT 
INCOM/INC* 
FLX,RLX,HOMEX 
FLY,RLY,HOMEY 
FLZ,RLZ,HOMEZ 
FLW,RLW,HOMEW 
FLX,RLX,HOMEX,FLY,RLY,HOMEY 
FLZ,RLZ,HOMEZ,FLW,RLW,HOMEW 
FLE,RLE,HOMEE,FLF,RLF,HOMEF 
FLG,RLG,HOMEG,FLH,RLH,HOMEH 
LSCOM/LSC*