Galil DMC-1700 Manual De Usuario

Descargar
Página de 253
46 • Chapter 3 Connecting Hardware 
DMC-1700/1800 
For the DMC-1800 there is a separate LSCOM and INCOM for IN1-IN8, home, and limit switches for axes 1-4 and 
for IN9-16, home, and limit switches for axes 5-8.  The jumpers are located on the DMC-1800 at JP3 and JP13, 
respectively. 
 
INCOM
IN1
IN2
IN3
IN4
IN5
IN6
IN7
IN8
ABORT
LSCOM
FLSX
RLSX
HOMEX
FLSY
RLSY
HOMEY
Additional Limit
Switches(Dependent on
Number of Axes)
(XLATCH) (YLATCH) (ZLATCH) (WLATCH)
 
Figure 3-1.  The Optoisolated Inputs. 
Note: The DMC-1700 controllers with 5 or more axes have IN9 through IN16 also connected to INCOM.  The 
DMC-1800 controllers have a separate INCOM (labeled INC) for IN9 through IN16. 
Using an Isolated Power Supply 
To take full advantage of opto-isolation, an isolated power supply should be used to provide the voltage at the input 
common connection.  When using an isolated power supply, do not connect the ground of the isolated power to the 
ground of the controller.  A power supply in the voltage range between 5 to 24 Volts may be applied directly (see 
Figure 3-2).  For voltages greater than 24 Volts, a resistor, R, is needed in series with the input such that 
1 mA < V supply/(R + 2.2K
Ω) < 11 mA