Emerson 1F97-1277 Manuel De Montage

Page de 12
3
Single Stage Connections
Refer to equipment manufacturers' instructions for specific system 
wiring information .
This thermostat is designed to operate a single-transformer or two-
transformer system .
You can configure the thermostat for use with the following systems:
SINGLE STAGE gas, oil or electric .
HEAT PUMP TYPE 1 (HP 1). Single stage compressor system; gas 
or electric backup .
After wiring, see INSTALLER CONFIGURATION section for proper 
thermostat configuration.
Single Stage System with Single Transformer
Single Stage with Two Transformers
Heat Pump Systems
Single
Stage
(SS)
Energiz-
ed in
Cool
Mode
Energized 
in Heat
or Off
Mode
System
O
RH
+
B
CLASS II
TRANSFORMER
HOT
24VAC
NEUTRAL
120VAC
W
G
C*
-
Jumper
Energized
on call
for Cool
(Com-
pressor)
Blower/
Circula-
tor Fan
Energiz-
ed on
call for
Cool &
for Heat
(if ELE
is sel-
ected)
24 Volt
(Hot)
Cool
DC 
supply
voltage
to re-
mote
Temp-
erature
Sensor
Remote
Temp-
erature
Sensor
signal
DC
Return
to
Remote
Temp-
erature
Sensor
Energized
on call for
Heat
Third
wire for
3-wire
zone
valve
Diagnostic
Indicator
(See
Note  
 
 )
Y
RC
S
6
L
{
To Remote Temperature Sensor
24 Volt
(Hot)
Heat
24 Volt
Com-
mon
(option-
al)
1
*Common connection required for fault or
  malfunction indication and remote sensor .
*24 VAC common connection
optional for system operation .
**Dual fuel de-energizes 
compressor when auxiliary heat is 
energized .
Required for fault or malfunction indi-
cation, remote temperature sensor, or 
for continuous backlight operation .
 
 WIRING CONNECTIONS
Single
Stage
(SS)
Energized 
in Cool
Mode
Energized 
in Heat,
Off Mode
System
O
RH
+
B
CLASS II
TRANSFORMER
HOT
24VAC
NEUTRAL
120VAC
W
G
C*
-
Energized
on call
for Cool
(Com-
pressor)
Blower/
Circula-
tor Fan
Energiz-
ed on
call for
Heat or
Cool
(if ELE
is sel-
ected)
24 Volt
(Hot)
Cool
DC 
supply
voltage
to re-
mote
Temp-
erature
Sensor
Remote
Temp-
erature
Sensor
signal
DC
Return
to
Remote
Temp-
erature
Sensor
Energized
on call for
Heat
Third wire
for 3-wire
zone valve
Y
RC
S
6
L
{
To Remote Temperature Sensor
24 Volt
(Hot)
Heat
24 Volt
Com-
mon
(option-
al)
CLASS II
TRANSFORMER
120VAC
HOT
24VAC
NEUTRAL
HEATING
COOLING
Diagnostic
Indicator
(See
Note  
 
 )
1
Jumper
Remove Jumper Wire
between RH & RC
NOTE: If continuous backlight or hardwired 
power input are desired but do not function 
in both HEAT and COOL modes, cut the 
heating transformer 24V wires and tape off . 
Connect the neutral circuit disconnected 
from the heating transformer to the neutral 
circuit of the cooling transformer . Discon-
nect the wire to the RH terminal and install 
a jumper between RH and RC . Depending 
on the system requirements, replace the 
cooling transformer with a 75VA class II 
transformer if needed .
*Common connection required for fault or
  malfunction indication and remote sensor .
NOTE ➀: Connection for Call for Service diagnostic indicator compatible with mechanical or electronic condenser control with Comfort Alert
TM
 .
Heat
Pump 1
(HP1)
Energized 
in Cool
& Off
Mode
Energiz-
ed in
Heat/
Emer-
gency
Mode
System
O
RH
+
B
CLASS II
TRANSFORMER
HOT
24VAC
NEUTRAL
120VAC
W
G
C*
-
Jumper
1st
Stage
Heat 
& Cool
(Com-
pressor)
    **
Blower/
Circula-
tor Fan
Energiz-
ed on
call for
Heat or
Cool
24 VAC
(Hot)
Cool
DC 
supply
voltage
to re-
mote
Temp-
erature
Sensor
Remote
Temp-
erature
Sensor
signal
DC
Return
to
Remote
Temp-
erature
Sensor
Auxil-
iary &
Emer-
gency
Heat
1st
Stage
Power
Closed
Conn-
ection
for
3-wire
zone
valve
Diagnostic 
Indicator
(See 
Note ) 
 
  
Y
RC
S
6
L
{
To Remote Temperature Sensor
24 VAC
(Hot)
Heat
24 VAC
Common
(optional)
Comfort
Alert II module
or similar
malfunction
module