RAD Data comm IPmux-16 Manuel D’Utilisation
Chapter 1 Introduction
IPmux-16 Installation and Operation Manual
1-18 Technical Specifications
Ethernet Port:
LINK
OFF when line is not active
ON when line is OK
ACT
OFF when no activity
ON when a frame is being transmitted or
received on the line
received on the line
FDX
OFF when half duplex
ON when full duplex
ON when full duplex
100M OFF when 10 MHz
ON when 100 MHz
E1/T1 Port:
SYNC ON when the port is synchronized (no alarm)
OFF when signal loss, LOF or AIS is detected
(local alarm)
(local alarm)
BLINKS when RDI is detected (remote alarm)
Note: All LEDs are green and ON after power-up.
Power
Physical
Environment
Humidity
1 or 2 power supplies
40W, 100 to 240 VAC, 50/60 Hz
–36 to –72 VDC (–48 VDC nominal)
Height 6.6 cm / 2.55 in (1.5U)
Height 6.6 cm / 2.55 in (1.5U)
Width 43.2 cm / 19 in
Depth 35 cm / 13.78 in
Depth 35 cm / 13.78 in
Weight 4.0 kg / 8.8 lb
Temperature: 0 to 45°C / 32 to 110°F
Up to 90%, non-condensing
Temperature: 0 to 45°C / 32 to 110°F
Up to 90%, non-condensing