3-18 
Parameters 
None
 
Description 
Use the alarm registration-error enable command to enable the registration error alarm. 
Use the undo alarm registration-error enable command to disable the registration error alarm. 
The system generates a registration error alarm when an error occurs during the registration of an 
ONU. 
By default, the registration error alarm is enabled. 
Examples 
# Enable the registration error alarm on OLT 3/0/1.  
<Sysname> system-view 
[Sysname] interface olt3/0/1 
[Sysname-Olt3/0/1] alarm registration-error enable 
alarm remote-stable enable 
Syntax 
alarm remote-stable enable 
undo alarm remote-stable enable 
View 
OLT port view, FTTH view 
Default Level 
2: System level 
Parameters 
None
 
Description 
Use the alarm remote-stable enable command to enable the remote stable alarm. 
Use the undo alarm remote-stable enable command to disable the remote stable alarm. 
The system generates a remote stable alarm in case of an ONU misuse in the system, for example, 
when an OAM 2.0 ONU and an OAM 3.3 ONU are mixed in the same system. (All ONUs in the same 
system must adopt the same OAM version.) 
The local stable alarm differs from the remote stable alarm in the following way: 
 
The local stable alarm is generated at the OLT side. 
 
The remote stable alarm is generated at the ONU side and will be reported to the OLT. 
By default, the remote stable alarm is enabled. 
Related commands: alarm local-stable