3com S7906E Guide D’Installation Rapide

Page de 155
 
1-35 
Table 1-57 Description of the fan status LEDs 
LED 
Description 
OK 
ON: The fans operate normally. 
OFF: The fans are faulty or out of position. 
FAIL 
ON: The fans are faulty or out of position. 
OFF: The fans operate normally. 
 
LPU status LEDs (SLOT0 through SLOT11) 
SLOT0 through SLOT11: The LEDs indicate the status of the LPUs seated in the twelve slots. 
Table 1-58 Description of the LPU status LEDs 
LED 
Description 
RUN 
ON/OFF: The LPU is faulty or out of position. 
Blinking: The LPU is operating normally. 
ALM 
OFF: The LPU is operational or out of position. 
ON: The LPU is faulty. 
 
 
If the RUN LED flashes at a high frequency, the card is in the startup process, but is not yet operational. 
At system startup, the ALM LED will be ON for a while, but it does not mean that the card is faulty 
 
ACTIVE LED 
The ACTIVE LED shows the active/standby status of the LSQ1SRP1CB0. If the ACTIVE LED is ON, 
the LSQ1SRP1CB0 is active; if OFF, the LSQ1SRP1CB0 is standby. 
RESET button 
A reset button is provided on the LSQ1SRP1CB0 for you to reset the card when necessary. 
Salience VI-Plus SRPU-LSQ1SRPD0 
Applicable models 
S7903E 
S7906E 
S7910E 
S7906E-V 
Technial specifications 
Table 1-59 Technical specifications of the LSQ1SRPD0 
Item 
Specifications 
CPU 
MIPS64, 600 MHz 
Boot ROM 
512 KB 
Flash memory 
64 MB