3com S7906E Guide D’Installation Rapide

Page de 155
 
1-37 
10/100Base-TX management Ethernet port 
Using an RJ-45 connector, the 10/100Base-TX management Ethernet port can be connected to a local 
PC for switch program loading and switch debugging, or connected to a remote NMS for remote 
management. 
Table 1-61 Specifications of the 10/100Base-TX management Ethernet port 
Item 
Specifications 
Connector type 
RJ-45 
Number of interfaces 
Interface speed 
10/100 Mbps, half/full duplex 
Cable medium and maximum transmission 
distance 
Category-5 twisted pair, with a maximum 
transmission distance of 100 m (328.08 ft.) 
Function 
Used for switch software upgrade and network 
management 
 
 describes the status LEDs of the 10/100Base-TX management Ethernet port. 
Table 1-62 Description of the status LEDs of the 10/100Base-TX management Ethernet port 
LED 
Description 
LINK 
OFF: No link is present. 
ON: A link is present. 
ACT 
OFF: No data is being transmitted or received. 
Blinking: Data is being transmitted or received. 
 
System LEDs 
System status LEDs 
The LEDs on the card panel indicate the statuses of the power modules, fans, LPUs seated in the 
twelve slots, and LSQ1SRPD0 itself. 
Power status LEDs 
PWR: The power status LEDs show the status of the power modules. 
Table 1-63 Description of the power status LEDs 
LED 
Description 
ON: The power modules operate normally. 
OK 
OFF: The power module is faulty or out of position. 
ON: The power module is faulty or out of position. 
FAIL 
OFF: The power modules are operational or out of position. 
 
Fan status LEDs 
FAN: The LEDs show the status of the fan tray.