Spec. No. 581126000 (Model 700
NVBA
Issue AD, November 23, 2009 
 
Page 17 of 123 
 
This document is property of Emerson Network Power, Energy Systems, North America, Inc. and contains confidential and proprietary information owned by Emerson Network Power, Energy 
Systems, North America, Inc.  Any copying, use, or disclosure of it without the written permission of Emerson Network Power, Energy Systems, North America, Inc. is strictly prohibited. 
13) Order as required additional options per Lists 
, and 
14) Order as required any additional accessories described under 
 
List 2:  Supplemental Bay Common Equipment (Power and Distribution) 
(located next to Main Bay) 
Features 
♦  Provides common equipment for one bussed “power and distribution” bay rated for up to 2000 amperes of 
distribution.  Includes interbay power busbars and communications cabling. 
♦  Mounts to either left or right side of a 
 Main Bay. 
♦  Accepts one (1) Distribution Cabinet (options are 3-Row or 4-Row cabinet). 
♦  Accepts one (1) Module Mounting Assembly.  The Module Mounting Assembly can consist of one (1), two 
(2), three (3), or four (4) factory interconnected 8-position Module Mounting Shelves.  Each Module 
Mounting Shelf in a Module Mounting Assembly provides eight (8) mounting positions for Rectifier 
Modules (PCUs). 
or 
Can be configured for “distribution only” (no Module Mounting Assembly). 
Restrictions 
Order maximum of one (1) List 2 or 
 per Power System. 
Cannot be used when List 5 is ordered.  Order List 2 or List 5, not both. 
Supplemental Bays DO NOT accept Converter Modules.  DO NOT order List 
 for Supplemental Bays. 
List 2 Supplemental Bay DOES NOT accept List 
 Distribution Cabinet 
(List 21 and 22 are not provided with connection points for interbay busbars.) 
Rear access is required for installation of inter-bay busbars. 
Ordering Notes 
1)  Order a relay rack per '
' under ACCESSORY DESCRIPTIONS.  If required, order Relay Rack 
Transition Plates per '
' under ACCESSORY DESCRIPTIONS.  Relay rack must be same height as relay rack ordered 
.  A ship loose option is available, as described in '
' under ACCESSORY 
DESCRIPTIONS. 
2)  Order one (1) List 
 or 
 Distribution Cabinet. 
3)  Order up to four (4) Distribution Bus Panels as required per '
' and the 
capacity of the Distribution Cabinet ordered. 
4)  Order one (1) List 
 (interface components for one (1) Module Mounting Assembly).  Order a Module 
Mounting Assembly per PD588705101/PD588705102/PD588705103/PD58805104.  List 30 is factory 
connected to the Module Mounting Assembly ordered. 
or 
Order Supplemental Bay 'Distribution Only' option per List 
5)  Order Rectifier Modules (PCUs) per List 
 as required. 
6)  Order one (1) Module Mounting Position Blank Cover Panel, 
, for each empty module 
mounting position in the system. 
7)  Order fuses and/or circuit breakers, as required, per '
' under ACCESSORY 
DESCRIPTIONS. 
8)  Order input and load distribution lugs, as required, per '
' under ACCESSORY 
DESCRIPTIONS.