Temco DV1000/1200/1400 Series
76657
FP387
SIT Valve and pilot 
HI
LO
OFF
ON
OFF
PI
LO
T
O
FF
E
A
PILOT
THTP
TP
TH
Pilot Screw
Wall Switch
(not supplied)
Thermopile
Pilot
Ignitor
To Piezo
Thermocouple
Manifold Pressure
Supply Pressure
IN
OUT
FP387
Fig. 37  Pilot and valve wiring.
Recommended Maximum Lead Length
 (Double Wire)
When Using Wall Switch or Thermostat 
 
 
Wire Size 
Max. Length
 
14 ga. 
50’ (15.2 m)
 
16 ga. 
32’ (9.8 m)
 
18 ga. 
20’ (6 m)
 
20 ga. 
15’ (4.6 m)
 
22 ga. 
10’ (3 m)
NOTE: All Models are supplied with 15’ (4.6 m) of 
double wire for use with a wall switch.
CAUTION: Do not wire 120V power to mil-
livolt switches or thermostats.
Managing Heat Output
The heat output from the appliance may be controlled 
by adjusting the main gas valve. Reference lighting 
instructions on Page 28 and chart on Page 34 showing 
inputs at all the settings.
The main gas valve may be adjusted anywhere be-
tween high and low to give the desired combination of 
flame aesthetics and heat output. 
HI
LO
T155
PS24
hi/lo knob
11/10/03  djt
Turn knob clockwise
to increase flame
Turn knob 
counterclockwise
to decrease flame
Fig. 38  Flame adjustment knob.
Fan Operation
The fan operates automatically - turn the knob on the 
speed control to adjust to the desired speed.  The fan 
will turn on as the fireplace comes up to operating tem-
perature. After the unit has been turned off and the unit 
cooled to below a useful heat output range the fan will 
shut off automatically.
Flame Characteristics
It is important to periodically perform a visual check of 
the pilot and burner flames. Compare them to Figure 
39.
If the flame patterns appear abnormal, contact a quali-
fied service provider for service and adjustment.
Pilot Burner Adjustment
1.  Adjust pilot screw to provide proper sized flame.
2.  Leak test.
F584-703
Honeywell
& PSE
pilot flames
3/8” - 1/2”
(10 - 13 mm)
F584-703
Fig. 39  Correct flame appearance.