TransCore 05716 Manuel D’Utilisation

Page de 210
Encompass 4 Reader System Guide
7-16
P0
no parity (factory default)
P1
even parity
P2
odd parity
D0
00 ms end-of-line delay (fixed)
One space is required between each value. For example, if factory default settings are 
assigned, the reader message is
MAIN B5 S0 P0 D0
indicating 9600 baud, one stop bit, no parity, and 0 ms end-of-line delay.
Note:  The information transmitted in response to command #522 applies to data and 
command mode operation only. While operating in download mode, default communi-
cations parameters are always used.
524 Display Appended Information Status
Command #524 displays the information being appended to the reader transmissions. 
Command #31N appends information.
Reader response:
IDAP T<0 to 1> D<0 to 1> X<0 to 1>
where
T0
Time not appended
T1
Time appended
D0
Date not appended
D1
Date appended
X0
Auxiliary information not appended (factory default)
X1
Auxiliary information appended
One space is required between each value. For example, if factory-default settings are 
assigned, the reader response is
IDAP T1 D1 X0
indicating time and date appended, and auxiliary information not appended.
Note:  Time and date may be appended to ID codes, error messages, presence without 
tag reports, and input status change reports. Auxiliary information may only be 
appended to ID codes, presence without tag reports, and input change reports.