Commands
7-17
525 Display Communications Protocol Status
Command #525 displays the status of command #61N Selected Communications 
Protocol, command #614N Selected Mode of Flow Control, and command #612NN 
ECP Timeout.
Reader response:
ECPS P<0 to 1> T<01 to FF> X<0 to 2> S0
where
P0
Basic protocol enabled (factory default)
P1
ECP enabled
Txx
ECP timeout where xx = 01 to FE (hexadecimal)
Timeout (ms) = 50 * xx
If xx = FF timeout disabled
X0
Flow control disabled
X1
Software flow control enabled (factory default)
X2
Hardware flow control enabled
S0
start of message character is #
For example, if factory default settings are assigned, the reader message is:
ECPS P0 TFE X1 S0
which means basic protocol enabled, an ECP timeout of 254 (12,700 ms, 12.7 sec), 
software flow control enabled, and start of message character is #.
527 Display RF Status
Command #527 displays the current status of the RF module. The reader response 
indicates whether RF is controlled externally by the host, set by command #640N RF 
Control, or internally by input set by command #641 (not applicable to the MPRR). 
RF always controlled by Sense0 and Sense1 when reader is in MPRR mode. See 
. Command #527 also displays the current 
RF status and the uniqueness timeout.
Note:  If you enter RF settings using command #642NN, the display command for RF 
output frequency, F is “Fxx” and indicates use of the backward-compatible frequency 
entry method.
Reader response:
RFST C<0 to 1> O<0 to 1> T<1 to 3> Fxxx Rxx Gxx Axx Ixx
where
C0
RF controlled by host
C1
RF controlled by presence sensor on input0, the red/green pair 
(factory default)
O0
RF off