Configuring the Multiprotocol Rail Reader
8-13
Note:  The MPRR internal timing varies depending on the operative tag read mode 
and the type of tag in the read field. 
See section 
 and section 
To set ID separation parameters
1.
Ensure that the host computer is in command mode.
2.
Enter command #4100 to select a separation of one ID; enter command #4101 
to select a separation of two IDs. Press ENTER.
Reports
The MPRR can be configured to transmit presence without tag reports and input status 
change reports. A presence without tag report is transmitted in data mode only, and 
only if the system has a presence detector
. This report is sent if a presence is detected 
without the detection of a valid tag ID. See sections 
an
29.
If configured with command #82N Select Input Status Change Report Option to 
transmit input status change reports, the reader will transmit a message to the host 
computer any time the inputs change state. Input status change reports are transmitted 
in data mode only. Input status change reporting is disabled by default. See 
for information on message formats.
To set presence reporting
1.
Ensure that the host computer is in command mode.
2.
Enter command #529 to display presence input status and press ENTER. P0 
indicates presence without tag reports disabled (factory default), and P1 indicates 
presence without tag reports enabled.
3.
Enter command #6901 to enable presence without tag reports, or enter 
command #6900 to disable presence without tag reports (factory default). Press 
ENTER
.
To set input status change reporting
1.
Ensure that the host computer is in command mode.
2.
Enter command #560 to display input status change report options and press 
ENTER
.
EO = input status change reports disabled (factory default)
E1 = input status change reports enabled
M0 = reporting disabled (factory default)
M1 = changes on input0 reported
M2 = changes on input1 reported
M3 = changes on either input reported