Tyco Safety Products/Sensormatic UMEXCAL Manuel D’Utilisation
Preliminary
AMS-1070 CONTROLLER INSTALLATION GUIDE (8200-0127-06, REV. 0)
6 of 13
Connecting a split-receiver
(dual-aisle) configuration
If you are connecting two non-alarming antennas
and one alarming antenna to the wiring harness,
use Table 5 and Table 6 to connect the antennas.
and one alarming antenna to the wiring harness,
use Table 5 and Table 6 to connect the antennas.
Table 5. Aisle A connector
Cable Wire
Color
Pin
Red 1
Non-alarming 1
Black 2
Both antennas
Shield
3
Black 4
Red 5
Brown 6
Orange 7
Yellow 8
Green 9
Blue 10
Violet 11
Red 5
Brown 6
Orange 7
Yellow 8
Green 9
Blue 10
Violet 11
Alarming
Gray 12
For zone identification to work properly, the
alarming antenna must be installed so the piezo on
it faces non-alarming antenna 1.
alarming antenna must be installed so the piezo on
it faces non-alarming antenna 1.
Table 6. Aisle B connector
Cable Wire
Color
Pin
Red 1
Black 2
Black 2
Non-alarming 2
Shield 3
Black 4
Red 5
Brown 6
Orange 7
Yellow 8
Green 9
Blue 10
Violet 11
Black 4
Red 5
Brown 6
Orange 7
Yellow 8
Green 9
Blue 10
Violet 11
Unused
Gray 12
Connecting the Noise
Canceling Antennas
Canceling Antennas
The table below lists the pinouts for the Noise/Rx
Coils connector.
Coils connector.
Pin Signal
1 Shield
2
1 Shield
2
Coil A Return
3 Coil
A
4
Coil B Return
5 Coil
B
6 Shield
7
Inhibit Aisle A
8
Inhibit Aisle B
9 Digital
Ground
10
I/O Port 1
11
I/O Port 2
12
I/O Port 3
13 Digital
Ground
14 Shield
Connecting to Relays in the
Controller
Controller
The table below lists the pinouts for the Relay
connector.
connector.
Pin Signal
1
1
Relay A Arm
2
Relay A NC
3
Relay A NO
4 Shield
5
5
Relay B Arm
6
Relay B NC
7
Relay B NO
8 Shield
Ground
9
System Error Arm
10
System Error NC
11
System Error NO
12 Shield
13 Shield
14 Shield
13 Shield