13 
 
 
4.  Drill  three  12mm  diameter  holes  in  the  wall  on  the  marked  locations,  and 
insert the expansion pipes. 
5.  Fix base station to the wall with M8 x 80 expansion bolts.   
 
Connect Cable 
3.6
3.6.1  Requirement for Cable Laying 
General requirements: 
 
Bending radius requirement of feeder cable: 7/8
” > 250mm, 4/5” > 380mm.   
 
Bending radius requirement of jumper cable: 1/
4” > 35mm,1/2” (super soft) > 50mm,
1/2
” (ordinary)>127mm. 
 
Bending  radius  requirement  of  power  cable  and  grounding  cable:  >  tripled  of  the 
diameter of cable. 
 
Binding the cables according the type of the cable, the intertwining and crossing is 
forbidden. 
 
The label should be paste after the cable laying. 
Grounding laying requirement: 
 
The grounding cable must connect to the grounding point. 
 
The grounding cable must be  separate with the signal cables, remaining a certain 
distance to avoid the interruption of signal.