Baicells Technologies Co. Ltd. BRU3510 Manuel D’Utilisation

Page de 27
 
 
  Installation Environment 
2.3
2.3.1  Locational Requirements 
Environments with high-temperature, harmful gases, unstable voltage, big vibration, high 
noise  or  exposed  to  flammable,  explosive,  electromagnetic  interference  (large  radar 
station, transmitting station, transformer substation) are not suitable for the operation of 
BRU3510, and thus should be avoided. Places prone to have impounded water, soaking, 
leakage, or condensation, should also be avoided.   
In the construction process, factors like climate, hydrology, geology, earthquake, electric 
power, and transportation should be taken into consideration so that a proper location can 
be chosen to meet the communication engineering environmental requirements, as well 
as the technical requirements of network planning and communication equipment. 
2.3.2  Environmental Requirements 
gives the base station’s environmental requirements on temperature, humidity, 
and voltage.   
Table 2-2 Environmental Requirements of the Base Station 
Item 
Range 
Typical value 
Humidity 
-35℃~ 55℃ 
25℃ 
Relative humidity 
(no 
condensation) 
0% ~ 100% 
5% ~ 100% 
Safety voltage 
- 58V ~ -42V 
-48V 
 
2.3.3  Power Requirements 
BRU3510  base  station  adopts  -48V  DC  power  supply.  For  the  safety  and  reliability  of 
device, we have the following suggestions. 
 
Remote DC power supply, in general, AC power supply is 100V ~ 270V, the distance 
of AC power supply to the device is less than 30 meters. 
 
If the static exceeds a certain range, it will lead to great damage to the circuit and the 
whole device.