6. The installation is complete.
Connect Cable
4.6
4.6.1 Requirement for Cable Laying
General requirements:
Bending radius requirement of feeder cable: 7/8
” > 250mm, 4/5” > 380mm
Bending radius requirement of jumper cable: 1/
4” > 35mm,1/2” (super soft) > 50mm,
1/2
” (ordinary)>127mm
Bending radius requirement of power cable and grounding cable: > tripled of the
diameter of cable
The minimum bend radius of the optical fiber is the 20 times of the diameter of
optical fiber.
Binding the cables according the type of the cable, the intertwining and crossing is
forbidden.
The label should be paste after the cable laying.
Optical fiber laying requirement:
The circling and twisting is forbidden during the laying.
The binding on the turning is forbidden.
The pulling and weigh down the optical fiber is forbidden.
The redundant optical fiber must enwind the dedicated device.
Grounding laying requirement:
The grounding cable must connect to the grounding point.
The grounding cable must be separate with the signal cables, remaining a certain
distance to avoid the interruption of signal.
4.6.2 Connect GPS Antenna
1. Connect one end of the GPS RF cable to the GPS antenna. It is necessary for the
GPS antenna interfaces to be weatherproofed. Refer to 3.6 Weatherproof Protection
for more detail.
2.
Connect the other end of the GPS RF cable to the GPS interface of the eNodeB,
which also need the weatherproof protection.