Baicells Technologies Co. Ltd. MBS1105 Manuel D’Utilisation

Page de 31
Baicells mBS1105 Base Station Installation Guide(V100R001C00,02).docx 
16 
 
6.  The installation is complete. 
 
Connect Cable 
4.6
4.6.1  Requirement for Cable Laying 
General requirements: 
 
Bending radius requirement of feeder cable: 7/8
” > 250mm, 4/5” > 380mm   
 
Bending radius requirement of jumper cable: 1/
4” > 35mm,1/2” (super soft) > 50mm,
1/2
” (ordinary)>127mm 
 
Bending  radius  requirement  of  power  cable  and  grounding  cable:  >  tripled  of  the 
diameter of cable 
 
The  minimum  bend  radius  of  the  optical  fiber  is  the  20  times  of  the  diameter  of 
optical fiber. 
 
Binding the cables according the type of the cable, the intertwining and crossing is 
forbidden. 
 
The label should be paste after the cable laying. 
Optical fiber laying requirement: 
 
The circling and twisting is forbidden during the laying. 
 
The binding on the turning is forbidden. 
 
The pulling and weigh down the optical fiber is forbidden. 
 
The redundant optical fiber must enwind the dedicated device. 
Grounding laying requirement: 
 
The grounding cable must connect to the grounding point. 
 
The grounding cable must be  separate with the signal cables, remaining a certain 
distance to avoid the interruption of signal. 
4.6.2  Connect GPS Antenna 
1.  Connect one end of the GPS RF cable to the GPS antenna. It is necessary for the 
GPS antenna interfaces to be weatherproofed. Refer to 3.6 Weatherproof Protection 
for more detail. 
2. 
Connect the other end of the GPS RF cable to the GPS  interface of the eNodeB, 
which also need the weatherproof protection.