 Normal Operation 
31
Page
 
Turn off the electrical power supply and close the manual gas shutoff valve 
and the manual water control valve before servicing. 
MAINTENANCE AND SERVICE 
 
 
 
 
  Be sure that all openings for combustion and ventilation air are not blocked. 
  The venting system should be checked annually for any leaks, corrosion, blockages or damage. 
  The burner should be checked annually for dust, lint, grease or dirt. 
  Keep the  area  around the  water heater  clear.  Remove any combustible materials,  gasoline or any 
flammable vapors and liquids. 
  In accordance with all local codes and common safety practices, Water discharged from the pressure 
relief vale can cause severe burns instantly from scalding.  DO NOT touch the pressure relief valve. 
  If the relief valve discharges periodically, it may be due to thermal expansion in a closed water supply 
system. Contact the water supplier or local plumbing inspector on how to correct this situation. 
  Visual check of burner flames (see below) through the burner window in the burner assembly located 
at the middle of the water heater. 
 
 
 
 
 
 
Hydro‐Smart recommends having the unit checked once a year or as necessary by a licensed technician. 
If repairs are needed, any repairs should be done by a licensed technician. 
 
 
 
UNIT DRAINING
 
 
1.  Close the manual gas shut off valve. 
2.  Turn  off  power  to  the  unit  and  wait  a  couple  of 
seconds. Turn on again. 
3.  Wait 30 seconds, and then turn off power to the unit, 
yet again. 
4.  Close the water shut off valve. 
5.  Open  all  hot  water  taps  in  the  house.  When  the 
residual  water  flow  has  ceased,  close  all  hot  water 
taps. 
6.  Have  a  bucket  or  pan  to  catch  the  water  from  the 
unit’s drain plugs. Unscrew the two drain plugs (Large 
and small) to drain all the water out of the unit.  
7.  Wait  a  few  minutes  to  ensure  all  water  has 
completely drained from unit. 
8.  Securely screw the drain plugs back into place. Hand‐ 
tighten only. 
WARNING 
Drain Plug  
(Large) 
Water Valve 
Drain Plug 
(Small) 
Gas Valve 
Unsatisfactory
Satisfactory 
Unsatisfactory
Blue flame 
Red or Yellow 
flame 
Flame 
blowing up