 Normal Operation 
30
Page
 
Only pipes within the water heater are protected by the freeze protection 
system.  Any water pipes (hot or cold) located outside the unit will not be 
protected.  Properly protect and insulate these pipes from freezing. 
Household Flow Rates
Taken from UPC 2006
FLOW 
  The flow rate through the water heater is limited to a 
maximum of 6.6 GPM.  
  The temperature setting, along with the supply 
temperature of the water will determine the flow rate 
output of the unit.   
  Please refer to the temperature vs. gallons per minute 
chart on p. 41 to determine the likely flow rates based 
on your local ground water temperature and your 
desired outlet water temperature. 
  Based on the United States Department of Energy 
method of testing water heater output, the water heater is rated for 172 gallons per hour (GPH) or 2.9 
gallons per minute (GPM) for Natural Gas, and 184 GPH or 3.1 GPM for Propane, when raising the 
water temperature by 77F (from 58F to 135F).  
  Refer to the table to the top right for typical household plumbing fixture flow rates to determine 
what the water heater can do in a household application.  
 
 
 
FREEZE PROTECTION SYSTEM 
  This unit comes equipped with heating blocks to protect it against damages associated with freezing.  
  For this freeze protection system to operate there has to be electrical power to the unit. Damage to 
the  heat  exchanger  caused  by  freezing  temperatures  due  to  power  loss  is  not  covered  under  the 
warranty.  In cases where power losses can occur, consider the use of a backup power supply. 
  The freeze protection system will activate when the surrounding and/or outside temperatures drop 
below 36.5°F (2.5°C). 
  For the Hydro‐Smart 115 models: 
 
In  any  areas  subject  to  freezing  temperatures,  Hydro‐Smart  highly  recommends  an  indoor 
installation  with  an  indoor  model.    In  such  an  installation,  freezing  issues  can  only  occur  if 
cold air enters through the venting into the heat exchanger, whether by negative pressures 
within the installation location or by strong outside winds.
 
 
Hydro‐Smart  also  highly  recommends  the  use  of  a  back  flow  vent  damper  to  minimize  the 
amount of cold air entering through the exhaust venting when the water heater is off.
 
  It is the installer’s responsibility to be aware of freezing issues and take all preventative measures.  
Hydro‐Smart will not be responsible for any damage to the heat exchanger as a result of freezing.  
  If you will not be using your heater for a long period of time: 
1.  Completely drain the unit of water. Refer to p. 31.  
2.  Disconnect power to your heater.      
    This will keep your unit from freezing and being damaged.
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Appliance / Use 
Flow Rate (GPM) 
Lavatory Faucet 
1.0 
Bath Tub 
4.0 – 10.0 
Shower 
2.0 
Kitchen Sink 
1.5 
Dishwasher 
1.5 
Washing machine 
4.0 