Q-Logic MKII-BASE16 Manuel D’Utilisation

Page de 138
GigWorks MKII-16 Switch Model MKII-BASE16
Installer's/User's Manual            59003-01 Rev. A
Reference Information  
A-3
Reference Information
Gb/s, even though backplanes 
supply up to 32 Gb/s.
Maximum Frame Sizes:  .............
Model MKII-BASE16 — 2148 bytes (2112-
byte payload) for all classes of service 
supported by the Switch.
Model MKII-STD16 — Class 1:  2148 
bytes (2112 byte payload) Class 2 or 
Class 3:  548 bytes (512 byte payload)
System Processor:  ......................
Superscalar 40-MHz Intel i960HA
Switch Maintainability
Maintenance Strategy:   ...............
FRU-based:
GBIC Modules
Power supplies/fans
AC input fuses
Does not require enclosure opening for any
reason, including:
GBIC insertion to populate/activate 
new ports
GBIC replacement
Redundant power supply replacement
Does not require system interruption for:
GBIC insertion to populate/activate 
new ports
GBIC replacement
Redundant power supply replacement
Backup Components:  .................
Hot-swappable spare power supply and 
integral cooling fan
Diagnostics:   ...............................
Power-On-Self-Test (POST) tests all 
functionality except media modules.
Field selectable Continuous Test tests all 
functionality including media modules.
Fabric Management
Fabric Management: ....................
Simple Name Server, Alias Server, SNMP,
the Windows NT™ or Windows 95™-based
Switch Management Utilities, and an 
optional Web-based Java application 
User Interface:   ...........................
LED indicators, Chassis Switch panel
Maintenance Interfaces:  .............
Ethernet 10BASE-T
Ethernet Connector:  ...................
RJ-45