Q-Logic MKII-BASE16 Manuel D’Utilisation
GigWorks MKII-16 Switch Model MKII-BASE16
Installer's/User's Manual 59003-01 Rev. A
Installer's/User's Manual 59003-01 Rev. A
Reference Information
A-3
Reference Information
Gb/s, even though backplanes
supply up to 32 Gb/s.
supply up to 32 Gb/s.
Maximum Frame Sizes: .............
Model MKII-BASE16 — 2148 bytes (2112-
byte payload) for all classes of service
supported by the Switch.
supported by the Switch.
Model MKII-STD16 — Class 1: 2148
bytes (2112 byte payload) Class 2 or
Class 3: 548 bytes (512 byte payload)
Class 3: 548 bytes (512 byte payload)
System Processor: ......................
Superscalar 40-MHz Intel i960HA
Switch Maintainability
Maintenance Strategy: ...............
FRU-based:
GBIC Modules
Power supplies/fans
AC input fuses
Power supplies/fans
AC input fuses
Does not require enclosure opening for any
reason, including:
reason, including:
GBIC insertion to populate/activate
new ports
GBIC replacement
Redundant power supply replacement
new ports
GBIC replacement
Redundant power supply replacement
Does not require system interruption for:
GBIC insertion to populate/activate
new ports
GBIC replacement
Redundant power supply replacement
new ports
GBIC replacement
Redundant power supply replacement
Backup Components: .................
Hot-swappable spare power supply and
integral cooling fan
integral cooling fan
Diagnostics: ...............................
Power-On-Self-Test (POST) tests all
functionality except media modules.
Field selectable Continuous Test tests all
functionality including media modules.
functionality except media modules.
Field selectable Continuous Test tests all
functionality including media modules.
Fabric Management
Fabric Management: ....................
Simple Name Server, Alias Server, SNMP,
the Windows NT™ or Windows 95™-based
Switch Management Utilities, and an
optional Web-based Java application
the Windows NT™ or Windows 95™-based
Switch Management Utilities, and an
optional Web-based Java application
User Interface: ...........................
LED indicators, Chassis Switch panel
Maintenance Interfaces: .............
Ethernet 10BASE-T
Ethernet Connector: ...................
RJ-45