Q-Logic MKII-BASE16 Manuel D’Utilisation

Page de 138
GigWorks MKII-16 Switch Model MKII-BASE16
Installer's/User's Manual            59003-01 Rev. A
Reference Information  
A-5
Reference Information
Switch Environmental
Operational Temperature: ............
10 to 40°C (50 to 104°F)
Operating Humidity: ...................
25 to 80%, non-condensing
Operating Altitude:   ....................
0 to 3048m (0 to 10,000 feet)
Operating Vibration:   ..................
During/after (in any axis) of magnitude:
2.54mm (0.1”) from 5 to 14 Hz
0.1G from 14-300 Hz
Operating Shock:   .......................
During/after (in any axis) of magnitude:
1.0G for 15 m seconds
Air flow: ......................................
Cooling air flows from the front to the back.
Heat output:   ...............................
600 BTU/hr fully populated
Non-Operational Temperature:....
-40 to 65°C ( -40 to 149F)
Non-Operating Humidity: ...........
25 to 90%, non-condensing
Non-Operating Altitude:  ............
0 to 15240m (0 to 50,000 feet)
Non Operating Vibration:   ..........
(In any axis):  0.5G from 10 to 300 Hz
Non Operating Shock:   ...............
(In any axis):  8.0G for 15 m seconds
Switch Regulatory Certifications
Safety Standards: .........................
UL1950
CSA 22.2 No. 950
EN60950
Emissions Standards:  .................
FCC Part 15B Class A
VCCI Class A ITE
CISPR 22, Class A
EN 55022, Class A
Voltage Fluctuations:   .................
EN 61000-3-3
Harmonics:...................................
EN 61000-3-2
Immunity:   ..................................
EN 50082-1:1997
Marking:   ....................................
FCC Part 15 
UL (United States)
UL (Canada)
TUV
VCCI
CE