Q-Logic MKII-BASE16 Manuel D’Utilisation
GigWorks MKII-16 Switch Model MKII-BASE16
Installer's/User's Manual 59003-01 Rev. A
Installer's/User's Manual 59003-01 Rev. A
Reference Information
A-5
Reference Information
Switch Environmental
Operational Temperature: ............
10 to 40°C (50 to 104°F)
Operating Humidity: ...................
25 to 80%, non-condensing
Operating Altitude: ....................
0 to 3048m (0 to 10,000 feet)
Operating Vibration: ..................
During/after (in any axis) of magnitude:
2.54mm (0.1”) from 5 to 14 Hz
0.1G from 14-300 Hz
0.1G from 14-300 Hz
Operating Shock: .......................
During/after (in any axis) of magnitude:
1.0G for 15 m seconds
Air flow: ......................................
Cooling air flows from the front to the back.
Heat output: ...............................
600 BTU/hr fully populated
Non-Operational Temperature:....
-40 to 65°C ( -40 to 149F)
Non-Operating Humidity: ...........
25 to 90%, non-condensing
Non-Operating Altitude: ............
0 to 15240m (0 to 50,000 feet)
Non Operating Vibration: ..........
(In any axis): 0.5G from 10 to 300 Hz
Non Operating Shock: ...............
(In any axis): 8.0G for 15 m seconds
Switch Regulatory Certifications
Safety Standards: .........................
UL1950
CSA 22.2 No. 950
EN60950
CSA 22.2 No. 950
EN60950
Emissions Standards: .................
FCC Part 15B Class A
VCCI Class A ITE
CISPR 22, Class A
EN 55022, Class A
VCCI Class A ITE
CISPR 22, Class A
EN 55022, Class A
Voltage Fluctuations: .................
EN 61000-3-3
Harmonics:...................................
EN 61000-3-2
Immunity: ..................................
EN 50082-1:1997
Marking: ....................................
FCC Part 15
UL (United States)
UL (Canada)
TUV
VCCI
CE
UL (United States)
UL (Canada)
TUV
VCCI
CE