Q-Logic MKII-BASE16 Manuel D’Utilisation

Page de 138
A-4
Reference Information
GigWorks MKII-16 Switch Model MKII-BASE16
59003-01 Rev. A           Installer's/User's Manual 
Reference Information
Switch Agent :   ...........................
Allows a network management station to 
obtain configuration values, traffic 
information, and failure data pertaining to 
the Fibre Channels via SNMP through the 
Ethernet interface.
TFTP:  .........................................
Trivial File Transfer Protocol (TFTP)— 
Allows the network management station to 
configure the Switch Management  interface, 
load new Switch control-processor and 
management processor firmware into their 
respecive Flash memories,  reset the Switch, and 
test file transfers between the management 
station and the Switch’s Ethernet port.
Switch Mechanical
Chassis Dimensions:  ..................
Refer to Figures A-1 and A-2. 
Enclosure Types:  ........................
The chassis is shipped with four rubber feet
on the bottom for secure stacking. Cabinet 
Mounting Brackets are also shipped with 
the chassis. You may mount these brackets 
on the front or back of the chassis for 
mounting in a Standard 19-inch EIA rack 
with either the chassis back or front facing 
the front of the equipment rack.
Chassis Support:   ........................
The chassis 
MUST be supported by a shelf 
or rails when rack-mounted
Chassis Weight:   .........................
20 kg (45 lbs) maximum configuration
Switch Electrical
Power source loading:   ...............
1.7 Amps maximum at 90 to 137 Vac
0.9 Amps maximum at 180 to 265 Vac
Each Power Supply:  ...................
140 Watts
Operating voltage: .......................
90 to 137 Vac; 47 to 63 Hz
180 to 265 Vac; 47 to 63 Hz
Input Fuse Type: ..........................
There are two input fuses. Each 
fuse is a 4 Amp Slow-Blow, 250V
Littelfuse P/N  218004 or equivalent